The increase in speed of the high-speed atomic force microscopy (HS-AFM) compared to that of the conventional AFM made possible the first-ever visualisation at the molecular-level of the activity of an antimicrobial peptide on a membrane. We investigated the medically prescribed but poorly understood lipopeptide Daptomycin under infection-like conditions (37 °C, bacterial lipid composition and antibiotic concentrations). We confirmed so far hypothetical models: Dap oligomerization and the existence of half pores. Moreover, we detected unknown molecular mechanisms: new mechanisms to form toroidal pores or to resist Dap action, and to unprecedently quantify the energy profile of interacting oligomers. Finally, the biological and medical relevance of the findings was ensured by a multi-scale multi-nativeness—from the molecule to the cell—correlation of molecular-level information from living bacteria (Bacillus subtilis strains) to liquid-suspended vesicles and supported-membranes using electron and optical microscopies and the lipid tension probe FliptR, where we found that the cells with a healthier state of their cell wall show smaller membrane deformations.
Background It is important to know the biomechanical properties of an allograft. This is because when looking to do a transplant of a tendon, the tendon must have very similar biomechanical properties to the original tendon. To use tendon allografts, it is critical to properly sterilize the tendon before implantation. In past decades, several sterilization procedures have been used. This study aimed to systematically evaluate the existing literature to compare the values of failure load/ultimate strength and Young’s modulus of elasticity of different sterilization methods on commonly used tendon allografts. Five major scientific literature databases (Web of Science, Science Direct, Scopus, PLOS ONE, Hindawi) and additional sources were used. Results Studies used had to show a particular sterilization method. Studies were identified to meet the following inclusion criteria: is a controlled laboratory study, gamma irradiation (dose reported), and other sterilization methods. Search for publications dated between 1991 and March 31st, 2020. The database search and additional sources resulted in 284 records. Two hundred thirty records eliminated during the screening for various reasons. The number of articles used in the final synthesis was 54. Conclusions Identified sterilization methods (gamma irradiation, ethylene oxid, supercritical carbon dioxide (SCCO2), BioCleanse, Electron Beam) are offered as a catalog of potential methods. As a result of the broadness of the present research, it provides an overview of sterilization methods and their effect on the mechanical properties (failure load and Young’s modulus of elasticity) of tendons. It does not stand for the state-of-the-art of any single process. Based on a systematic literature review, we recommend freezing and gamma irradiation or electron beam at 14.8–28.5 kGy. These methods are effective at keeping or improving the mechanical properties, while fully sterilizing the inside and the outside of the tendon. Other sterilization method (ethylene oxide, supercritical carbon dioxide (SCCO2), BioCleanse) deteriorated the mechanical properties. These methods are not recommended.
BackgroundIt is important to know the biomechanical properties of an allograft. This is because when looking to do a transplant of a tendon, the tendon must have very similar biomechanical properties to the original tendon. To use tendon allografts, it is critical to properly sterilize the tendon before implantation. In past decades, several sterilization procedures have been used. This study aimed to systematically evaluate the existing literature to compare the values of failure load/ultimate strength and Young’s modulus of elasticity of different sterilization methods on commonly used tendon allografts. Five major scientific literature databases (Web of Science, Science Direct, Scopus, PLOS ONE, Hindawi) and additional sources were used.ResultsStudies used had to show a particular sterilization method. Studies were identified to meet the following inclusion criteria: is a controlled laboratory study, gamma irradiation (dose reported), and other sterilization methods. Search for publications dated between 1991 and March 31st, 2020. A total of 54 articles have been included. Data collected from the full-text assessment included: a) author and date, b) type of tendon, c) type of sterilization, d) sterilization dose, and g) measured and calculated parameters. Different types of sterilization methods used before tendon durability testing have been identified and categorized.ConclusionsIdentified sterilization methods (gamma irradiation, dry ice, supercritical carbon dioxide (SCCO2), BioCleanse, Electron Beam) are offered as a catalog of potential methods.As a result of the broadness of the present research, it provides an overview of sterilization methods. It does not stand for the state-of-the-art of any single process.
Background The use of tendon allografts for orthopedic repair has gained wide acceptance in recent years, most notably in anterior cruciate tendon reconstruction. Multiple studies support the use of tendon allografts and the benefits of its use are well accepted and understood. One of the important criteria of the use of tendon allografts is statistically similar histological and biomechanical properties to autographs. The aim of this systematic literature review is to investigate and categorize existing clamps used in the determination of the biomechanical properties of tendons such as maximum load, maximum strength, modulus of elasticity, ultimate strain, and stiffness. A variety of clamps for use during the endurance test of tendons were categorized according to the temperature used during the measurement. The clamps are divided into three groups: room temperature, cooled and heated clamps. The second goal of our review is to overview of clamps on the following aspects: name of clamp, author and date, type of clamps, type of endurance test (static or dynamic), type preloading (dynamic or static), type of tendon and measured and calculated parameters, and summarize in Table 3, as a comprehensive catalogue. Methods This systematic review was carried out in keeping with the PRISMA 2020 E&E and the PRISMA-S guidelines and checklists. A search was conducted for publications dating between 1991 and February 28th 2022 through three electronic databases (Web of Science, Scopus, and PubMed). We used Critical Appraisal Skills Program checklist to check the quality of included articles. Results The database search and additional sources resulted in 1725 records. 1635 records eliminated during the screening for various reasons (case report, other languages, book chapter, unavailable text/conference abstract, unrelated topic). The number of articles used in the final synthesis was 90. A variety of clamps for use during the endurance test of tendons were identified and categorized according to the temperature used during the measurement. Based on this, the clamps are divided into three groups: room temperature, cooled or heated clamps. Conclusions On the basis of the systematic literature review, mechanical parameters determined by usage with cooled clamps proved to be more reliable than with those at room temperature and with heated clamps. The collected information from the articles included name of clamp, author and date, type of clamps, type of endurance test (static or dynamic), type preloading (dynamic or static), type of tendon and measured and calculated parameters given in Table 3. summarized. The main advantage of the cooled clamps is that there is no limit to the type and length of the tendon. This study provides an overview of clamps and does not represent the modernity of any method.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.