In middle-aged Caucasian men, low serum albumin is associated with an increased risk of VTE, consistent with a linear dose-response relationship. The association is independent of and not modified by inflammation. Key messages • Serum albumin may be associated with future risk of venous thromboembolism (VTE); however, the shape, nature, magnitude and consistency of the association is uncertain. • In a population-based prospective cohort study, low serum albumin was associated with an increased risk of VTE in a linear dose-response manner and this association was independent of and not modified by inflammation. • Serum albumin concentrations may play a role in the development of VTE.
Background Healthcare cannot achieve net-zero carbon without addressing operating theatres. The aim of this study was to prioritize feasible interventions to reduce the environmental impact of operating theatres. Methods This study adopted a four-phase Delphi consensus co-prioritization methodology. In phase 1, a systematic review of published interventions and global consultation of perioperative healthcare professionals were used to longlist interventions. In phase 2, iterative thematic analysis consolidated comparable interventions into a shortlist. In phase 3, the shortlist was co-prioritized based on patient and clinician views on acceptability, feasibility, and safety. In phase 4, ranked lists of interventions were presented by their relevance to high-income countries and low–middle-income countries. Results In phase 1, 43 interventions were identified, which had low uptake in practice according to 3042 professionals globally. In phase 2, a shortlist of 15 intervention domains was generated. In phase 3, interventions were deemed acceptable for more than 90 per cent of patients except for reducing general anaesthesia (84 per cent) and re-sterilization of ‘single-use’ consumables (86 per cent). In phase 4, the top three shortlisted interventions for high-income countries were: introducing recycling; reducing use of anaesthetic gases; and appropriate clinical waste processing. In phase 4, the top three shortlisted interventions for low–middle-income countries were: introducing reusable surgical devices; reducing use of consumables; and reducing the use of general anaesthesia. Conclusion This is a step toward environmentally sustainable operating environments with actionable interventions applicable to both high– and low–middle–income countries.
Introduction This study evaluates COVID-19 related patient risk, when undergoing management within one of the largest specialist centres in Europe, which rapidly implemented national COVID-19 safety guidelines. Method A prospective cohort study was undertaken in all patients who underwent surgical ( n = 1429) or non-operative ( n = 191) management during the UK COVID-19 pandemic peak (April–May 2020); all were evaluated for 30-day COVID-19 related death. A representative sample of elective/trauma/burns patients (surgery group, n = 729) were selected and also sub-analysed within a controlled cohort study design. Comparison was made to a random selection of non-operatively managed (non-operative group, n = 100) or waiting list (control group, n = 250) patients. These groups were prospectively followed-up and telephoned from the end of June (control group) or at 30 days post-first assessment (non-operative group)/post-operatively (surgery group). Results Complex general (9.2%, 136/1483) or regional (5.0%, 74/1483) anaesthesia cases represented 14.2% (210/1483) of operations undertaken. There were no 30-day post-operative (0/1429)/first assessment (0/191) COVID-19 related deaths. Neither the three sub-speciality plastic surgery, or non-operative groups, displayed increases in post-operative/first assessment symptoms in comparison to each other, or to control. The proportion of COVID-19 positive tests were: 7.1% (1/14) (non-operative), 5.9% (2/34) (burns) and 3.0% (3/99) (trauma); there were however no significant differences between these groups, the elective (0%, 0/54) and control (0%, 0/24) groups ( p = 0.236). Conclusion We demonstrate that even heterogeneous sub-speciality patient groups, who required operative/non-operative management, did not incur an increased COVID-19 risk compared to each other or to control. These highly encouraging results were achieved with described, rapidly implemented service changes that were tailored to protect each patient group and staff.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.