The effect of ultrasound on the permeability of blood vessels to nanoemulsion droplets was investigated using excised mouse carotid arteries as model blood vessels. Perfluorocarbon nanodroplets were formed by perfluoro-15-crown-5-ether (PFCE) and stabilized by poly(ethylene oxide)-co-poly(D,L-lactide) (PEG-PDLA) block copolymer shells. Nanodroplet fluorescence was imparted by interaction with FITC-dextran (molecular weight of 70,000 Da). The permeability of carotid arteries to nanodroplets was studied in the presence or absence of continuous wave (CW) or pulsed therapeutic 1-MHz ultrasound. The data showed that the application of ultrasound resulted in permeabilization of the vascular wall to nanodroplets. The effect of CW ultrasound was substantially stronger than that of pulsed ultrasound of the same total energy. No effect of blood vessel pre-treatment with ultrasound was observed.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.