Background
The ChAdOx1 nCoV-19 (AZD1222) vaccine has been approved for emergency use by the UK regulatory authority, Medicines and Healthcare products Regulatory Agency, with a regimen of two standard doses given with an interval of 4–12 weeks. The planned roll-out in the UK will involve vaccinating people in high-risk categories with their first dose immediately, and delivering the second dose 12 weeks later. Here, we provide both a further prespecified pooled analysis of trials of ChAdOx1 nCoV-19 and exploratory analyses of the impact on immunogenicity and efficacy of extending the interval between priming and booster doses. In addition, we show the immunogenicity and protection afforded by the first dose, before a booster dose has been offered.
Methods
We present data from three single-blind randomised controlled trials—one phase 1/2 study in the UK (COV001), one phase 2/3 study in the UK (COV002), and a phase 3 study in Brazil (COV003)—and one double-blind phase 1/2 study in South Africa (COV005). As previously described, individuals 18 years and older were randomly assigned 1:1 to receive two standard doses of ChAdOx1 nCoV-19 (5 × 10
10
viral particles) or a control vaccine or saline placebo. In the UK trial, a subset of participants received a lower dose (2·2 × 10
10
viral particles) of the ChAdOx1 nCoV-19 for the first dose. The primary outcome was virologically confirmed symptomatic COVID-19 disease, defined as a nucleic acid amplification test (NAAT)-positive swab combined with at least one qualifying symptom (fever ≥37·8°C, cough, shortness of breath, or anosmia or ageusia) more than 14 days after the second dose. Secondary efficacy analyses included cases occuring at least 22 days after the first dose. Antibody responses measured by immunoassay and by pseudovirus neutralisation were exploratory outcomes. All cases of COVID-19 with a NAAT-positive swab were adjudicated for inclusion in the analysis by a masked independent endpoint review committee. The primary analysis included all participants who were SARS-CoV-2 N protein seronegative at baseline, had had at least 14 days of follow-up after the second dose, and had no evidence of previous SARS-CoV-2 infection from NAAT swabs. Safety was assessed in all participants who received at least one dose. The four trials are registered at ISRCTN89951424 (COV003) and
ClinicalTrials.gov
,
NCT04324606
(COV001),
NCT04400838
(COV002), and
NCT04444674
(COV005).
Findings
Between April 23 and Dec 6, 2020, 24 422 participants were recruited and vaccinated across the four studies, of whom 17 178 were included in the primary analysis (8597 receiving ChAdOx1 nCoV-19 and 8581 receiving control vaccine). The data cutoff for these analyses was Dec 7, 2020. 332 NAAT-positive infections met the primary endpoint of symptomatic infection more t...
Background: The coronavirus disease 2019 (COVID-19) pandemic has highlighted the reliance on antigen detection rapid diagnostic tests (Ag-RDTs). Their evaluation at point of use is a priority. Methods: Here, we report a multi-centre evaluation of the analytical sensitivity, specificity, and clinical accuracy of the Mologic COVID-19 Ag-RDT by comparing to reverse transcriptase polymerase chain reaction (RT-qPCR) results from individuals with and without COVID-19 symptoms. Participants had attended hospitals in Merseyside, hospital and ambulance services in Yorkshire, and drive-through testing facilities in Northumberland, UK. Results: The limit of detection of the Mologic COVID-19 Ag-RDT was 5.0 x 102 pfu/ml in swab matrix with no cross-reactivity and interference for any other pathogens tested. A total of 347 participants were enrolled from 26th of November 2020 to 15th of February 2021 with 39.2% (CI 34.0-44.6) testing RT-qPCR positive for SARS-CoV-2. The overall sensitivity and specificity of the Mologic Ag-RDT compared to the reference SARS-CoV-2 RT-qPCR were 85.0% (95% CI 78.3-90.2) and 97.8% (95.0-99.3), respectively. Sensitivity was stratified by RT-qPCR cycle threshold (Ct) and 98.4% (91.3-100) of samples with a Ct less than 20 and 93.2% (86.5-97.2) of samples with a Ct less than 25 were detected using the Ag-RDT. Clinical accuracy was stratified by sampling strategy, swab type and clinical presentation. Mologic COVID-19 Ag-RDT demonstrated highest sensitivity with nose/throat swabs compared with throat or nose swabs alone; however, the differences were not statistically significant. Conclusions: Overall, the Mologic test had high diagnostic accuracy across multiple different settings, different demographics, and on self-collected swab specimens. These findings suggest the Mologic rapid antigen test may be deployed effectively across a range of use settings.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.