Objective. To investigate the effect of extent of revascularization in complex high-risk indicated patients (CHIP) undergoing Impella-protected percutaneous coronary intervention (PCI). Background. Complete revascularization has been shown to be associated with improved outcomes. However, the impact of more complete revascularization during Impella-protected PCI in CHIP has not been reported. Methods. A total of 86 CHIP undergoing elective PCI with Impella 2.5 or Impella CP between April 2007 and December 2016 from 2 high volume Italian centers were included. Baseline, procedural, and clinical outcomes data were collected retrospectively. Completeness of coronary revascularization was assessed using the British Cardiovascular Intervention Society myocardial jeopardy score (BCIS-JS) derived revascularization index (RI). The primary end-point was all-cause mortality. A multivariate regression model was used to identify independent predictors of mortality. Results. All patients had multivessel disease and were considered unsuitable for surgery. At baseline, 44% had left main disease, 78% had LVEF ≤ 35%, and mean BCIS-JS score was 10±2. The mean BCIS-JS derived RI was 0.7±0.2 and procedural complications were uncommon. At 14-month follow-up, all-cause mortality was 10.5%. At follow-up, 67.4% of CHIP had LVEF ≥ 35% compared to 22.1% before Impella protected-PCI. Higher BCIS-JS RI was significantly associated with LVEF improvement (p=0.002). BCIS-JS RI of ≤ 0.8 (HR 0.11, 95% CI 0.01- 0.92, and p = 0.042) was an independent predictor of mortality. Conclusions. These results support the practice of percutaneous Impella use for protected PCI in CHIP. A more complete revascularization was associated with significant LVEF improvement and survival.
Our study confirms the increased risk of cancer after transplantation and during dialysis, but showed that virus-related cancers only occur after post-transplant immunosuppression.
Objectives: To describe and report the results of an original technique for transfemoral (TF) transcatheter-aortic-valve-replacement (TAVR). Background: TF approach represents the commonest TAVR technique. The best technique for TF-TAVR is not recognized. Methods: We developed a less-invasive totally-endovascular (LITE) technique for TF-TAVR. The key aspects are: 1. precise TAVR access puncture using angiographic-guidewire-ultrasound guidance 2. radial approach as the "secondary access" (to guide valve positioning, to check femoral-access hemostasis and to manage eventual access-site complications) 3. non-invasive pacing (by retrograde left ventricle stimulation or by definitive pacemaker external programmer) The LITE technique has been systematically adopted at our Institution. Procedure details, complications and clinical events occurring during hospitalization were prospectively recorded. Major vascular complications and life-threatening or major bleedings were the primary study end-points. Results: A total of 153 consecutive patients referred for TF-TAVR were approached using the LITE technique. Mean predicted surgical operative mortality was 4.9% and mean TAVR predicted mortality was 3.9%. In 132 (86.3%) patients, TAVR was completed without the need for additional femoral artery access or transvenous temporary pacemaker implantation. Major vascular complications occurred in 2 (1.3%), life-threatening or major bleedings occurred in 4 (2.6%) patients. All-cause death occurred in 3 patients (2.0%).
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.