Capillary zone electrophoresis (CZE) of serum proteins is increasingly gaining impact in clinical laboratories. In this report, we evaluate automated capillary zone electrophoresis by Capillarys (Sebia, France). Within-run and between-run imprecision for the five electrophoretic fractions was <2% and <6%, respectively. Data obtained with Capillarys correlated with results obtained with agarose gel electrophoresis and Paragon CZE 2000 (Beckman Coulter, USA). Analysis of serum obtained from patients with inflammation, nephrotic syndrome, bisalbuminemia, and alpha1-antitrypsin deficiency revealed that Capillarys was able to detect these abnormalities. Two hundred thirty eight samples were analyzed by agarose gel electrophoresis, Capillarys, capillary electrophoresis using Paragon CZE 2000 system, and immunofixation. Sample selection was based on the presence of a disturbed morphology (e.g., spike) of the protein profile or hypogammaglobulinemia on agarose gel electrophoresis and/or Capillarys. Immunofixation revealed the presence of a monoclonal protein, oligoclonal bands, polyclonal pattern, and a normal profile in, respectively, 89, 66, 19, and 64 samples. With Capillarys, Paragon, and agarose gel electrophoresis, a spike and/or disturbed morphology of the profile was found in 222, 182, and 180 samples, respectively. In these samples, immunofixation was negative in 73 (33%), 46 (25%), and 39 (22%) samples, respectively. These data indicate that Capillarys has a lower specificity than agarose gel electrophoresis and Paragon 2000. Of the 89 samples with a monoclonal protein, Capillarys, Paragon, and agarose gel electrophoresis failed to detect, respectively, three, three, and one monoclonal protein(s). Interferences by radio-opaque agents, complement degradation products, fibrinogen, and triglycerides are described. In conclusion, automated capillary zone electrophoresis with Capillarys provides for reproducible, rapid, and reliable serum electrophoresis.
With respect to reproducibility, chromatographic resolution, speed of analysis and identification of Hb variants, the Tosoh G8 analyser can be considered to be state of the art.
We sought evidence of BCR/ABL transcripts in the peripheral blood of nine CML patients in complete clinical and cytogenetic remission after treatment by bone marrow transplantation (BMT) or interferon and in one patient who entered spontaneous remission. Six patients were investigated at different times during their follow-up. We compared results obtained with the polymerase chain reaction (PCR) using (a) a single-stage PCR comprising 30 cycles of amplification with selected oligomers, and (b) a two-stage procedure in which the reaction product from the first stage was subjected to a further 30 cycles with nested amplimers. Special care was taken to assess contamination, including for each patient simultaneous co-extraction of a negative control. Blood cells from all patients showed no evidence of BCR/ABL transcripts in the one-stage PCR but 9/17 specimens were positive in the two-stage procedure. Patients in complete remission for a long time (greater than 2 years) appeared negative. These results serve in part to explain the discordant findings reported in other studies and emphasize the importance of carefully selecting the technical conditions most likely to give results that are prognostically relevant for individual patients.
We discuss the similarities and differences between assays that utilise the different reference materials.
We evaluated the analytical performances of the new Sebia kit for quantification of hemoglobin fractions (HbA, HbF and HbA2) and structural hemoglobin variants on the Capillarys system. This automated capillary zone electrophoresis method uses an alkaline buffer with silica capillaries and spectrophotometric detection. Specimen stability was evaluated during 1 month. The reproducibility of migration and the imprecision of quantification were also investigated. Comparison with the Beckman P/ACE system was performed on 202 samples. A total of 131 subjects without any hematological abnormality were analyzed to establish the HbA2 reference ranges based on our local population. Quantification of the Hb fractions and variants exhibited excellent stability for 4 weeks of storage at 4 degrees C, with CVs < 0.3%. The imprecision of the migration normalized to that of HbA2 for all hemoglobins tested (fractions and variants) was low, with a CV of < 2.5%. At physiological and pathological levels, total imprecision ranged from 1.9% to 4.6% for HbA2, from 0.6% to 9.7% for HbF, and from 0.6% to 1% for HbS. Statistical analysis revealed a small proportional negative bias for HbA2 (-8.6%). Small systematic bias (-0.2%) and proportional bias (-28%) were observed for HbF. No statistically significant difference was found for HbS. The reference range for HbA2 was 2.1-3.2%. The Capillarys system is a fully automated and accurate system that gives high-resolution performance and displays appropriate characteristics for use as a routine method for the diagnosis of thalassemias and hemoglobinopathies.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.