International recommendations for determination of reference intervals have been recently updated, especially for small reference sample groups, and use of the robust method and Box-Cox transformation is now recommended. Unfortunately, these methods are not included in most software programs used for data analysis by clinical laboratories. We have created a set of macroinstructions, named Reference Value Advisor, for use in Microsoft Excel to calculate reference limits applying different methods. For any series of data, Reference Value Advisor calculates reference limits (with 90% confidence intervals [CI]) using a nonparametric method when n≥40 and by parametric and robust methods from native and Box-Cox transformed values; tests normality of distributions using the Anderson-Darling test and outliers using Tukey and Dixon-Reed tests; displays the distribution of values in dot plots and histograms and constructs Q-Q plots for visual inspection of normality; and provides minimal guidelines in the form of comments based on international recommendations. The critical steps in determination of reference intervals are correct selection of as many reference individuals as possible and analysis of specimens in controlled preanalytical and analytical conditions. Computing tools cannot compensate for flaws in selection and size of the reference sample group and handling and analysis of samples. However, if those steps are performed properly, Reference Value Advisor, available as freeware at http://www.biostat.envt.fr/spip/spip.php?article63, permits rapid assessment and comparison of results calculated using different methods, including currently unavailable methods. This allows for selection of the most appropriate method, especially as the program provides the CI of limits. It should be useful in veterinary clinical pathology when only small reference sample groups are available.
Reference values are used to describe the dispersion of variables in healthy individuals. They are usually reported as population-based reference intervals (RIs) comprising 95% of the healthy population. International recommendations state the preferred method as a priori nonparametric determination from at least 120 reference individuals, but acceptable alternative methods include transference or validation from previously established RIs. The most critical steps in the determination of reference values are the selection of reference individuals based on extensively documented inclusion and exclusion criteria and the use of quality-controlled analytical procedures. When only small numbers of values are available, RIs can be estimated by new methods, but reference limits thus obtained may be highly imprecise. These recommendations are a challenge in veterinary clinical pathology, especially when only small numbers of reference individuals are available.
Plasma clearance of creatinine was evaluated for assessment of glomerular filtration rate (GFR) in dogs. In 6 healthy dogs (Experiment 1), we determined 24-hour urine clearance of endogenous creatinine, plasma, and urine clearances of exogenous creatinine administered at 40, 80, and 160 mg/kg in a crossover design (linearity study), plasma iothalamate clearance, and plasma and urine clearances of 14 C-inulin. In Experiment 2, plasma creatinine and iothalamate clearances were compared, and a linearity study was performed as for Experiment 1 in 6 dogs with surgically induced renal impairment. Experiment 3 compared plasma creatinine clearance with plasma iothalamate clearance before and 3 weeks after induction of moderate renal impairment in 6 dogs. Plasma creatinine clearances were calculated by both noncompartmental and compartmental analyses. In Experiment 1, plasma inulin clearance was higher (P Ͻ .001) than other clearance values. Plasma creatinine clearances at the 3 dose rates did not differ from urine inulin clearance and each other. In Experiment 2, plasma creatinine clearances were about 14% lower than plasma iothalamate clearance (P Ͻ .05). In Experiment 3, decreases in GFR assessed by plasma clearances of iothalamate and creatinine were similar. Renal failure decreased the daily endogenous input rate of creatinine by 25%. Limiting sampling strategies for optimizing GFR calculation were proposed, allowing an error lower than 6.5% with 4 blood samples. These results suggest that determination of plasma creatinine clearance by a noncompartmental approach offers a reliable, inexpensive, rapid, and convenient means of estimating GFR in routine practice.
The objective of this study was to determine intra- and inter-observer variability of echocardiographic measurements in awake cats. Four observers with different levels of experience in echocardiography performed 96 echocardiographic examinations in four cats on four different days over a 3-week period. The examinations were randomized and blinded. The maximum within-day and between-day CV values were 17.4 and 18.5% for inter-ventricular septal thickness in diastole, 18.7 and 22.6% for left ventricular free-wall thickness in diastole, 9.8 and 14.9% for left ventricular end-diastolic diameter, 20.8 and 15.2% for left ventricular end-systolic diameter, and 21.2 and 18.4% for left ventricular shortening fraction. The maximum within-day CV values were most often associated with the least competent observer (i.e. the graduate student) and, the minimum CV values with the most competent observer (i.e. the associate professor in cardiology). A significant interaction between cat and observer was also evidenced. Thus, the most competent observer could not be replaced by any of the other observers.
LVFW myocardial velocities decreased from the endocardium to the epicardium and from base to apex, thus revealing intramyocardial radial and longitudinal velocity gradients. These indices could enhance conventional echocardiographic analysis of left ventricular function in dogs. Breed-specific reference intervals should be defined.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.