To explore the associations of exposure to carbon dioxide with adults’ response speed, 69 participants were invited to participate in the experiment conducted in an environmentally controlled chamber. Participants were exposed alone in three separate sessions, each lasting one hour, with a fixed ventilation rate, temperature and relative humidity level and the CO2 levels fixed at 600ppm, 1500ppm and 2100ppm, respectively. A validated neurobehavioral test battery, the Behavioural Assessment and Research System (BARS) was used to assess participants’ cognitive performance, and response times were collected. Response speed was assessed in ten different tests. After adjusting for potential confounders (age, gender, and education), results showed no significant differences in eight out of the ten neurobehavioral tests. For the Selective Attention test, participants responded faster (lower response time) under CO2 levels of 2100ppm compared to 600ppm (adj.β-coef. -17.57, 95% CI (-29.45, -5.68), p-value=0.004). For the Progressive Ratio Test, participants’ response times significantly decreased with CO2 levels increased. Results indicate no statistical link between CO2 levels and response speed, with only two out of ten comparisons being significant.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.