Objectives: To evaluate the effect of various medial patellofemoral ligament (MPFL) fixation techniques on patellar pressure compared with the native knee. Methods: A finite element model of the patellofemoral joint consisting of approximately 30,700 nodes and 22,200 elements was created from computed tomography scans of 24 knees with chronic lateral patellar instability. Patellar contact pressures and maximum MPFL graft stress at five positions of flexion (0°, 30°, 60°, 90°, and 120°) were analyzed in three types of MPFL reconstruction (MPFLr): (1) static/anatomic, (2) dynamic, using the adductor magnus tendon (AMT) as the femoral fixation, and (3) dynamic, using the quadriceps tendon as the attachment (medial quadriceps tendon-femoral ligament (MQTFL) reconstruction). Results: In the static/anatomic technique, the patellar contact pressures at 0° and 30° were greater than in the native knee. As in a native knee, the contact pressures at 60°, 90°, and 120° were very low. The maximum MPFL graft stress at 0° and 30° was greater than in a native knee. However, the MPFL graft was loose at 60°, 90°, and 120°, meaning it had no tension. In the dynamic MPFLr using the AMT as a pulley, the patellar contact pressures were like those of a native knee throughout the entire range of motion. However, the maximum stress of the MPFL graft at 0° was less than that of a native ligament. Yet, the maximum MPFL graft stress was greater at 30° than in a native ligament. After 30° of flexion, the MPFL graft loosened, similarly to a native knee. In the dynamic MQTFL reconstruction, the maximum patellar contact pressure was slightly greater than in a normal knee. The maximum stress of the MPFL graft was much greater at 0° and 30° than that of a native MPFL. After 30° of flexion, the MQPFL graft loosened just as in the native knee. Conclusions: The patellar contact pressures after the dynamic MPFLr were like those of the native knee, whereas a static reconstruction resulted in greater pressures, potentially increasing the risk of patellofemoral osteoarthritis in the long term. Therefore, the dynamic MPFLr might be a safer option than a static reconstruction from a biomechanical perspective.
Background Currently, there is uncertainty regarding the long-term outcome of medial patellofemoral ligament reconstructions (MPFLr). Our objectives were: (1) to develop a parametric model of the patellofemoral joint (PFJ) enabling us to simulate different surgical techniques for MPFLr; (2) to determine the negative effects on the PFJ associated with each technique, which could be related to long-term deterioration of the PFJ. Methods A finite element model of the PFJ was created based on CT data from 24 knees with chronic lateral patellar instability. Patella contact pressure and maximum MPFL-graft stress at five angles of knee flexion (0, 30, 60, 90 and 120°) were analysed in three types of MPFLr: anatomic, non-anatomic with physiometric behaviour, and non-anatomic with non-physiometric behaviour. Results An increase in patella contact pressure was observed at 0 and 30° of knee flexion after both anatomic and non-anatomic MPFLr with physiometric behaviour. In both reconstructions, the ligament was tense between 0 and 30° of knee flexion, but at 60, 90 and 120°, it had no tension. In the third reconstruction, the behaviour was completely the opposite. Conclusion A parametric model of the PFJ enables us to evaluate different types of MPFLr throughout the full range of motion of the knee, regarding the effect on the patellofemoral contact pressure, as well as the kinematic behaviour of the MPFL-graft and the maximum MPFL-graft stress. Electronic supplementary material The online version of this article (10.1186/s40634-019-0200-x) contains supplementary material, which is available to authorized users.
Dislocation after total hip arthroplasty (THA) remains a major issue and an important postsurgical complication. Impingement and subsequent dislocation are influenced by the design (head size) and position (anteversion and abduction angles) of the acetabulum and different movements of the patient, with external extension and internal f lexion the most critical movements. The aim of this study is to develop a computational tool based on a three-dimensional (3D) parametric finite element (FE) model and an artificial neural network (ANN) to assist clinicians in identifying the optimal prosthesis design and position of the acetabular cup to reduce the probability of impingement and dislocation. A 3D parametric model of a THA was used. The model parameters were the f emoral head size and the acetabulum abduction and anteversion angles. Simulations run with this parametric model were used to train an ANN, which predicts the range of movement (ROM) before impingement and dislocation. This study recreates different configurations and obtains absolute errors lower than 5.5º between the ROM obtained from the FE simulations and the ANN predictions. The ROM is also predicted for patients who had already suffered dislocation after THA, and the computational predictions confirm the patient's dislocations.Summarizing, the combination of a 3D parametric FE model of a THA and an ANN is a useful computational tool to predict the ROM allowed for different designs of prosthesis heads.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.