Background Heart rate variability ( HRV ) is associated with vascular risk factors for dementia, but whether HRV is associated with specific domains of cognitive performance is unclear. Methods and Results In the Multi‐Ethnic Study of Atherosclerosis (N=3018; mean age 59.3±9.2 years), we assessed the relationship of 10‐second HRV to scores on tests of global cognitive performance (Cognitive Abilities Screening Instrument), processing speed (Digit Symbol Coding), and working memory (Digit Span). HRV was computed as the SD of normal‐normal intervals (SDNN) and root mean square of successive differences (RMSSD) at Exam 1 (2000–2002) and Exam 5 (2010–2012). Cognitive tests were administered at Exam 5. We report regression coefficients (β [95% CI]) representing cognitive test score change per 2‐fold increase in HRV . After adjustment for age, race/ethnicity, sex, education, apolipoprotein E genotype, and cardiovascular risk factors and incident disease, higher Exam 1 (β=0.37 [0.06, 0.67]) and Exam 5 (β=0.31 [0.04, 0.59]) SDNN were associated with better Cognitive Abilities Screening Instrument performance. Higher Exam 1 (β=0.80 [0.17, 1.43]) and Exam 5 (β=0.63 [0.06, 1.20]) SDNN , and Exam 5 RMSSD (β=0.54 [0.01, 1.08]) were associated with better Digit Symbol Coding performance. Finally, higher Exam 5 SDNN was associated with better Digit Span performance (β=0.17 [0.01, 0.33]). Associations were attenuated after adjustment for resting heart rate. Conclusions Higher HRV is generally associated with better cognitive performance in this multi‐ethnic cohort of aging adults, and further study of the relationship of autonomic function to cognition is warranted.
The utility of thromboelastography/thromboelastometry currently has unvalidated clinical benefit in the assessment and reversal of coagulopathy among cirrhotic patients as compared to standard coagulation testing. A novel systematic review and meta-analysis was conducted in order to assess pooled outcome data among patients receiving thromboelastography/thromboelastometry as compared to standard coagulation testing. As compared to standard coagulation testing, there was a significant reduction in the number of patients requiring pRBC, platelet, and fresh frozen plasma transfusions among thromboelastography/thromboelastometry group with pooled OR 0.53 (95% CI 0.32–0.85; P = 0.009), 0.29 (95% CI 0.12–0.74; P = 0.009), and 0.19 (95% CI 0.12–0.31; P < 0.00001), respectively. Similarly, there was a significant reduction in number of pRBC, platelet, and fresh frozen plasma units transfused in the thromboelastography/thromboelastometry group with pooled MD −1.53 (95% CI −2.86 to −0.21; P = 0.02), −0.57 (95% CI −1.06 to −0.09; P = 0.02), and −2.71 (95% CI −4.34 to −1.07; P = 0.001), respectively. There were significantly decreased total bleeding events with pooled OR 0.54 (95% CI 0.31–0.94; P = 0.03) and amount of intraoperative bleeding during liver transplantation with pooled MD −1.46 (95% CI −2.49 to −0.44; P = 0.005) in the thromboelastography/thromboelastometry group. Overall, there was no significant difference in mortality between groups with pooled OR 0.91 (95% CI 0.63–1.30; P = 0.60). As compared to standard coagulation testing, a thromboelastography/thromboelastometry-guided approach to the assessment and reversal of cirrhotic coagulopathy improves overall number of patients exposed to blood product transfusions, quantity of transfusions, and bleeding events.
Objectives The objectives of this study were to compare short‐ and intermediate‐term clinical outcomes, procedural complications, TAVR prosthesis hemodynamics, and paravalvular leak (PVL) in stentless and stented groups. Background Valve‐in‐valve (ViV) transcatheter aortic valve replacement (TAVR) is an alternative to surgical redo for bioprosthetic valve failure. There have been limited data on ViV in stentless surgical valves. Methods We retrospectively analyzed 40 patients who underwent ViV TAVR in prior surgical bioprosthetic valves at Wake Forest Baptist Medical Center from October 2014 to September 2017. Eighty percent (32/40) ViV TAVRs were in stentless, while 20% (8/40) were in stented bioprosthetic valves. Results The primary mode of bioprosthetic valve failure for ViV implantation in the stentless group was aortic insufficiency (78%, 25/32), while in the stented group was aortic stenosis (75%, 6/8). The ViV procedure success was 96.9% (31/32) in stentless group and 100% in stented group (8/8). There were no significant differences in all‐cause mortality at 30 days between stentless and stented groups (6.9%, 2/31 versus 0%, 0/8, P = 0.33) and at 1 year (0%, 0/25 versus 0%, 0/5). In the stentless group, 34.4% (11/32) required a second valve compared to the stented group of 0% (0/8). There was a significant difference in the mean aortic gradient at 30‐day follow‐up (12.33 ± 6.33 mmHg and 22.63 ± 8.45 mmHg in stentless and stented groups, P < 0.05) and at 6‐month follow‐up (9.75 ± 5.07 mmHg and 24.00 ± 11.28 mmHg, P < 0.05), respectively. Conclusions ViV in the stentless bioprosthetic aortic valve has excellent procedural success and intermediate‐term results. Our study shows promising data that may support the application of TAVR in stentless surgical aortic valve. However, further and larger studies need to further validate our single center's experience.
Objectives: The objective was to compare outcomes of redo-aortic valve replacement (AVR) via surgical or transcatheter approach in prior surgical AVR with large percentage of prior stentless surgical AVR.Background: With the introduction of transcatheter aortic valve replacement (TAVR), patients with increased surgical risks now have an alternative to redo surgical AVR (SAVR), known as valve-in-valve (ViV) TAVR. Stentless prosthetic aortic valves present a more challenging implantation for ViV-TAVR given the lack of structural frame. Methods:We performed a retrospective study of 173 subjects who have undergone SAVR (N = 100) or ViV-TAVR (N = 73) in patients with prior surgical AVR at Wake Forest Baptist Medical Center from 2009 to 2019. Our study received the proper ethical oversight. Results:The average ages in redo-SAVR and ViV-TAVR groups were 58.03 ± 13.86 and 66.57 ± 13.44 years, respectively (p < 0.0001). The redo-SAVR had significantly lower STS (2.78 ± 2.09 and 4.68 ± 5.51, p < 0.01) and Euroscores (4.32 ± 2.98 and 7.51 ± 8.24, p < 0.05). The redo-SAVR group had higher percentage requiring mechanical support (8% vs. 0%, p < 0.05) and vasopressors (53% vs. 0%, p < 0.0001), longer length of stay (13.65 ± 11.23 vs. 5.68 ± 7.64 days, p < 0.0001), and inpatient mortality (16% vs. 2.78%, p < 0.005). At 30-day follow-up, redo-SAVR group had higher rates of acute kidney injury (10% vs. 0%, p < 0.01), however ViV-TAVR group had more new left bundle branch blocks (6.85% vs. 0%, p < 0.05). No significant differences regarding re-hospitalization rates, stroke, or death up to 1-year. Conclusion:Although the ViV-TAVR group had higher risk patients, there were significantly fewer procedural complications, shorter length of stay, and similar mortality outcomes up to 1-year follow-up.
Objectives This study aimed to assess the feasibility, efficacy, and safety of a novel percutaneous postprocedure closure technique for large arterial sheath removal with the use of two Perclose ProGlide (Abbott Vascular Devices, Redwood City, CA) devices. Background Postprocedural closing of large‐bore arteriotomies using the Perclose system can be difficult given the subsequent inability of the device to capture sufficient wall tissue. Methods Our study was a single‐center retrospective analysis of 22 consecutive patients who underwent large arteriotomy closure via the postclosure technique with a 12–16‐Fr sheath. Efficacy endpoints included successful deployment of the system and hemostasis. Safety endpoints included the incidence of major or minor vascular complications as defined by the Vascular Academic Research Consortium‐2 (VARC‐2) definitions at 30‐day follow‐up. Results The postclosure technique resulted in 100% technical success rate and no postprocedural bleeding or vascular complications. Conclusion Postclosure technique is a safe, highly effective, and feasible percutaneous method to achieve large‐bore arteriotomy hemostasis with low rates of major bleeding or vascular complications and favorable early outcome.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.