Background/Aims Food intolerance/malabsorption, particularly histamine intolerance (HIT), may cause nonspecific functional gastrointestinal and extraintestinal symptoms. We evaluated gastrointestinal and extraintestinal symptoms in patients with HIT. Methods In an analysis of outpatients’ charts we identified 133 patients, who presented with recurring nonspecific functional gastrointestinal, extraintestinal symptoms, and a diamine oxidase value <10 U/mL, indicative of HIT. A standardized anonymous questionnaire with symptoms of HIT based on known symptoms and the 4 histamine receptors including gastrointestinal, cardiovascular, respiratory and skin complaints was developed, and sent by mail to the patients. Results In the 62 patients that completed the questionnaire, bloating was the most common and most serious symptom. Other commonly reported gastrointestinal symptoms were postprandial fullness, diarrhea, abdominal pain, and constipation. The presence of 2 from a list of 24 symptoms resulted in 276 various symptom combinations. From calculated 2.024 possible combinations of 3 symptoms the patients with HIT presented 1.975 combinations. Conclusions The knowledge of this wide variability of symptoms and complex symptom combinations in patients with HIT may help to clinically recognize and diagnose HIT.
The aim of this study was to evaluate a laboratory-guided therapeutic algorithm of preoperative anemia. 335 patients with elective hip or knee arthroplasty were included in this retrospective before-after study. Group I (n = 101) underwent conventional preoperative procedures before algorithm implementation. Group II (n = 234) underwent algorithm-guided preoperative anemia management. A hemoglobin-level of 13 g/dL was the therapeutic cut-off for men and women. Reticulocyte hemoglobin content (CHr) and soluble transferrin receptor (sTfR)/log ferritin ratio were used in the form of the Thomas plot. Iron deficiency (ID) was substituted with 1000 mg iron intravenous (i.v.) and 10000 international units (I.U.) of erythropoiesis-stimulating agent (ESA) subcutaneous (s.c.) or i.v., anemia of chronic disease (ACD) (without functional ID) with 40000 I.U. ESA s.c. or i.v and additionally 200 mg iron i.v. Substituted anemic patients in Group II (n = 32) showed a distinctly higher preoperative (Hb-median 13 versus 11.95 g/dL) (P < 0.01) and postoperative (Hb-median 9.75 versus 9.0 g/dL) (P < 0.05) Hb level compared with untreated anemic patients in Group I (n = 24). In Group II red blood cell (RBC) units (35 units/234 patients) were reduced by 44% compared with Group I (27 units/101 patients). Algorithm-guided preoperative anemia management raises perioperative Hb-level and reduces blood use.
IntroductionRecently several diagnostic manufacturers have launched new 25-hydroxy-vitamin D (25[OH]D) assays, which are aligned to the National Institute of Standards and Technology (NIST) Standard Reference Materials (SRM) (NIST, Gaithersburg, Maryland). The aim of this study was to compare the performance of one liquid chromatography-tandem mass spectrometry (LC-MS/MS) method, one enzyme linked immunosorbent assay (ELISA), and one recalibrated and previous version of a chemiluminescence immunoassay (CLIA).Material and methodsSerum-aliquots of 198 patient samples from routine 25(OH)D analysis were measured by the ClinMass® LC-MS/MS Complete Kit (RECIPE Chemicals + Instruments GmbH, Munich, Germany), the ORGENTEC 25(OH)D3/D2 ELISA (ORGENTEC Diagnostika GmbH, Mainz, Germany), the recalibrated Immunodiagnostic Systems (IDS)-iSYS 25(OH)DS and the previous used IDS-iSYS 25(OH)D CLIA (Immunodiagnostic Systems Ltd, Boldon, United Kingdom). Bland-Altman and Deming regression analyses were calculated for methods comparison of all tested 25(OH)D assays. The LC-MS/MS method was defined as the reference method. Within-run and between-run precision measurements were performed for all methods with three different concentration levels.ResultsCompared to the LC-MS/MS method, the new IDS-iSYS 25(OH)DS and ORGENTEC 25(OH)D3/D2 assay demonstrated mean relative biases of 16.3% and 17.8%. The IDS-iSYS 25(OH)D assay showed the lowest mean bias of 1.5%. Deming regression analyses of the recalibrated IDS-iSYS 25(OH)DS and the ORGENTEC 25(OH)D3/D2 assay showed proportional differences, when compared to the reference method. All assays showed a within-run and between-run imprecision of ≤ 20% at each of the evaluated concentration levels.ConclusionsThe evaluated standardized immunoassays and LC-MS/MS are useful methods for measuring 25(OH)D serum-levels in clinical laboratories.
The aim of this study was to establish a retrospective evaluation and comparison of the hydrogen/methane (H2/CH4) breath test and genetic test (C/T−13910 polymorphism) results in lactose malabsorption testing. In total 263 consecutive patients with suspected lactose malabsorption were included in this study. They underwent the H2/CH4 breath test following the ingestion of 50 g lactose and were tested for the C/T−13910 polymorphism. In total 51 patients (19.4%) had a C/C−13910 genotype, indicating primary lactose malabsorption. Only 19 patients (7.2%) also had a positive H2/CH4 breath test. All in all 136 patients (51.69%) had a C/T−13910 and 76 patients (28.91%) a T/T−13910 genotype, indicating lactase persistence. Four patients (1.5%) with the C/T−13910 genotype and one patient (0.4%) with the T/T−13910 genotype had a positive H2/CH4 breath test result, indicating secondary lactose malabsorption. Cohen's Kappa measuring agreement between the two methods was 0.44. Twenty patients (7.6%) with a positive H2/CH4 peak within 60 minutes after lactose ingestion were classified as patients with lactose-dependent small intestinal bacterial overgrowth (SIBO). In conclusion, only moderate agreement between the breath test and the genetic test was shown. Secondary lactose malabsorption as well as preanalytical limitations of the combined H2/CH4 breath test procedure can cause discrepant results. This trial is registered with K-42-13.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.