PurposeThe placenta is a vital organ for the exchange of oxygen, nutrients, and waste products between fetus and mother. The placenta may suffer from several pathologies, which affect this fetal‐maternal exchange, thus the flow properties of the placenta are of interest in determining the course of pregnancy. In this work, we propose a new multiparametric model for placental tissue signal in MRI.MethodsWe describe a method that separates fetal and maternal flow characteristics of the placenta using a 3‐compartment model comprising fast and slowly circulating fluid pools, and a tissue pool is fitted to overlapping multiecho T2 relaxometry and diffusion MRI with low b‐values. We implemented the combined model and acquisition on a standard 1.5 Tesla clinical system with acquisition taking less than 20 minutes.ResultsWe apply this combined acquisition in 6 control singleton placentas. Mean myometrial T2 relaxation time was 123.63 (±6.71) ms. Mean T2 relaxation time of maternal blood was 202.17 (±92.98) ms. In the placenta, mean T2 relaxation time of the fetal blood component was 144.89 (±54.42) ms. Mean ratio of maternal to fetal blood volume was 1.16 (±0.6), and mean fetal blood saturation was 72.93 (±20.11)% across all 6 cases.ConclusionThe novel acquisition in this work allows the measurement of histologically relevant physical parameters, such as the relative proportions of vascular spaces. In the placenta, this may help us to better understand the physiological properties of the tissue in disease.
PurposeModel fitting of DCE-MRI data with non-linear least squares (NLLS) methods is slow and may be biased by the choice of initial values. The aim of this study was to develop and evaluate a linear least-squares (LLS) method to fit the two-compartment exchange and -filtration models. Methods ResultsThe LLS method is about 200 times faster, which reduces the calculation times for a 256×256 MR slice from 9 min to 3 sec. For ideal data with low noise and high temporal resolution the LLS and NLLS were equally accurate and precise. The LLS was more accurate and precise than the NLLS at low temporal resolution, but less accurate at high noise levels. ConclusionThe data show that the LLS leads to a significant reduction in calculation times, and more reliable results at low noise levels. At higher noise levels the LLS becomes exceedingly inaccurate compared to the NLLS, but this may be improved by using a suitable weighting strategy.
Key points Maternal supine sleep position in late pregnancy is associated with an increased risk of stillbirth. Maternal supine position in late pregnancy reduces maternal cardiac output and uterine blood flow. Using MRI, this study shows that compared to the left lateral position, maternal supine position in late pregnancy is associated with reduced utero‐placental blood flow and oxygen transfer across the placenta with an average 6.2% reduction in oxygen delivery to the fetus and an average 11% reduction in fetal umbilical venous blood flow. Abstract Maternal sleep position in late gestation is associated with an increased risk of stillbirth, though the pathophysiological reasons for this are unclear. Studies using magnetic resonance imaging (MRI) have shown that compared with lateral positions, lying supine causes a reduction in cardiac output, reduced abdominal aortic blood flow and reduced vena caval flow which is only partially compensated for by increased flow in the azygos venous system. Using functional MRI techniques, including an acquisition termed diffusion–relaxation combined imaging of the placenta (DECIDE), which combines diffusion weighted imaging and T2 relaxometry, blood flow and oxygen transfer were estimated in the maternal, fetal and placental compartments when subjects were scanned both supine and in left lateral positions. In late gestation pregnancy, lying supine caused a 23.7% (P < 0.0001) reduction in total internal iliac arterial blood flow to the uterus. In addition, lying in the supine position caused a 6.2% (P = 0.038) reduction in oxygen movement across the placenta. The reductions in oxygen transfer to the fetus, termed delivery flux, of 11.2% (P = 0.0597) and in fetal oxygen saturation of 4.4% (P = 0.0793) did not reach statistical significance. It is concluded that even in healthy late gestation pregnancy, maternal position significantly affects oxygen transfer across the placenta and may in part provide an explanation for late stillbirth in vulnerable fetuses.
Objective We hypothesised that a multi-compartment magnetic resonance imaging (MRI) technique that is sensitive to fetal blood oxygenation would identify changes in placental blood volume and fetal blood oxygenation in pregnancies complicated by earlyonset fetal growth restriction (FGR). Design Case-control study. Setting London, UK. Population Women with uncomplicated pregnancies (estimated fetal weight [EFW] >10th centile for gestational age [GA] and normal maternal and fetal Doppler ultrasound, n = 12) or earlyonset FGR (EFW <3rd centile with or without abnormal Doppler ultrasound <32 weeks GA, n = 12) were studied. Methods All women underwent MRI examination. Using a multicompartment MRI technique, we quantified fetal and maternal blood volume and feto-placental blood oxygenation. Main outcome measures Disease severity was stratified according to Doppler pulsatility index and the relationship to the MRI parameters was investigated, including the influence of GA at scan. Results The FGR group (mean GA 27 +5 weeks, range 24 +2 to 33 +6 weeks) had a significantly lower EFW compared with the control group (mean GA 29 +1 weeks; −705 g, 95% CI −353 to −1057 g). MRI-derived feto-placental oxygen saturation was higher in controls compared with FGR (75 AE 9.6% versus 56 AE 16.2%, P = 0.02, 95% CI 7.8-30.3%). Feto-placental oxygen saturation estimation correlated strongly with GA at scan in controls (r = −0.83). Conclusion Using a novel multimodal MRI protocol we demonstrated reduced feto-placental blood oxygen saturation in pregnancies complicated by early-onset FGR. The degree of abnormality correlated with disease severity defined by ultrasound Doppler findings. Gestational age-dependent changes in oxygen saturation were also present in normal pregnancies.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.