The search of sphericity evaluation is a time-consuming work. The minimum circumscribed sphere (MCS) is suitable for the sphere with the maximum material condition. An algorithm of sphericity evaluation based on the MCS is introduced. The MCS of a measured data point set is determined by a small number of critical data points according to geometric criteria. The vertices of the convex hull are the candidates of these critical data points. Two theorems are developed to solve the sphericity evaluation problems. The validated results show that the proposed strategy offers an effective way to identify the critical data points at the early stage of computation and gives an efficient approach to solve the sphericity problems.
The scanning acoustic microscope is used to detect the properties of films. The ultrasonic wave propagates in the films with thickness h, acoustic impedance Z2 between medium with acoustic impedance Z1. The echoes from upper and lower interfaces overlap and interfere. The echoes are transformed by FFT. The interference phenomena are observed in amplitude spectrum of echoes. The spectrum has periodic extreme values at fn, fn=nc/2h. When thickness h is known, sound velocity c2 of film can be calculated. According to the principle, the properties of films such as thickness, acoustic impendence and elastic modulus are evaluated by scanning acoustic microscopy. The experimental results are good accorded with the actual properties of specimens.
Scanning acoustic microscopy (SAM) is a powerful non-destructive testing tool used in the field of electronic package, micro-and nanomaterial and medication. The capability to distinct how minimum of defect is very important to detect the flaw in electronic packages. The detection resolution of SAM depends on the frequency of ultrasonic focus transducers. In this paper, the Multi-Gaussian Beam model to simulate the sound field of the focused transducers is discussed. Mainly the frequency domain imaging algorithm and 2D-Deconvolution method for better image quality and high resolution is analyzed. Finally, the calibration experiments for the detection resolution of 100MHZ transducer is carried out. In addition, the micro flaws with different dimensions are observed at different defocusing location. It is concluded that the detection resolution decreases with the deviating from focus plane, so the flaws should be sensitive on the focus area by precisely controlling the vertical position for better detection resolution.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.