There are significant differences in accuracy between RA surgery and FH surgery. It was demonstrated that the RA technique is superior to the conventional method in terms of the accuracy of pedicle screw placement.
The accuracy of robot-assisted pedicle screw placement is unstable and remains controversial. The purpose of this study was to determine the risk factors for unsatisfactory Renaissance robot-assisted pedicle screw placement. This was a retrospective study of prospective data. From January 2017 to March 2018, 136 robot-assisted pedicle screw placements were performed in our department for spinal diseases, and a total of 874 screws were evaluated. All screws were assessed by the Gertzbein and Robbins classification. A and B were defined as satisfactory. C, D, and E were defined as unsatisfactory. Intraoperative registration failures due to nontechnical reasons or intraoperative adjustment were also defined as unsatisfactory. According to the evaluated results, the screws were divided into the satisfactory group (Group A) and the unsatisfactory group (Group B). The satisfactory rate was defined as satisfactory screws (the screws in Group A)/total screws, and the accurate rate was defined as accuracy screws (the screws in Group A)/the screws implanted by the robot (total screws - failed registration screws - screws adjusted during the operation). The age, sex, BMI, and BMD as well as the type of disease, the degree of vertebral rotation and the type of screw placement (percutaneous implantation or open implantation) were compared between the two groups, with the assessment of potential risk factors for unsatisfactory robot-assisted screw placement using logistic regression. A total of 874 screws were evaluated; there were 759 screws in Group A and 115 screws in Group B. The satisfactory rate was 86.8% (759/874), and the accuracy rate of the robot-placed screws was 94.4% (759/804). After logistic regression analysis, the independent risk factors were identified as obesity (OR 5.357 [95% CI 2.897–9.906], p < 0.01), osteoporosis, vertebral rotation and the presence of congenital scoliosis (OR 9.835 [95% CI 4.279–22.604], p < 0.01), particularly for severe osteoporosis (T < −3.5) and severe vertebral rotation (III-IV). According to the results of this study, obesity, osteoporosis and congenital scoliosis are risk factors for unsatisfactory robot-assisted screw placement. Furthermore, for surgeons in the initial stage of using a robot, we suggest avoiding cases in which a single risk factor or multiple risk factors exist to ensure the safety of the operation and to help augment the confidence of the surgeons.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.