Linear surgical staplers reduce rates of surgical adverse events (bleeding, leaks, infections) compared to manual sutures thereby reducing patient risks, surgeon workflow disruption, and healthcare costs. However, further improvements are needed. Ethicon Gripping Surface Technology (GST) reloads, tested and approved by regulatory authorities in combination with powered staplers, may reduce surgical risks through improved tissue grip. While manual staplers are used in some regions due to affordability, clinical data on GST reloads used with manual staplers are unavailable. This study compared surgical adverse event rates of manual staplers with GST vs standard reloads. These data may be used for label changes in China and Latin America. Patients and Methods: Patients undergoing general or thoracic surgery between October 1, 2015 and August 31, 2021 using ECHELON FLEX™ manual staplers with GST or standard reloads were identified from the Premier Healthcare Database. GST reloads were compared to standard reloads for non-inferiority in bleeding and anastomotic leak for general surgery. Secondary outcomes included sepsis for general surgery, and bleeding and prolonged air leak for thoracic surgery. Covariate balancing was performed using stable balancing weights. Results: The general and thoracic surgery cohorts contained 4571 (GST: 2780; standard: 1791) and 814 (GST: 514; standard: 300) patients, respectively. GST reloads were non-inferior to standard reloads for bleeding and anastomotic leak (adjusted cumulative incidence ratio: 1.02 [90% CI: 0.71, 1.45] and 1.03 [90% CI: 0.72, 1.46], respectively) for general surgery. Compared with standard reloads, GST reloads had a similar incidence of sepsis (2.2% vs 2.1%) for general surgery and lower incidences of bleeding (9.5% vs 16.0%) and prolonged air leak (12.6% vs 14.0%,) for thoracic surgery. Conclusion: GST reloads, compared to standard reloads, used with ECHELON FLEX™ manual staplers had comparable perioperative bleeding and anastomotic leak for general surgery, and lower incidences of safety events for thoracic surgery.
Purpose To compare outcomes of non-donor patients undergoing radical nephrectomy using fixed-height gripping surface (FHGS) vs variable-height Tri-Staple™ (VHTS) reloads for transection of the renal vessels. Patients and Methods Using the Premier Healthcare Database of US hospital discharge records, we selected non-donor patients undergoing inpatient radical nephrectomy with dates of admission between 1 October 2015, and 31 December 2020 (first=index admission). The primary outcome was in-hospital hemostasis-related complications (hemorrhage, acute posthemorrhagic anemia, and/or procedure to control bleeding) during the index admission. Secondary outcomes included index admission intraoperative injury, blood transfusion, conversion from minimally invasive to open surgery, total hospital costs, length of stay (LOS), discharge status, and mortality as well as 30-day all-cause inpatient readmission. We used stable balancing weights to balance the FHGS and VHTS groups on numerous patient, procedure, and hospital/provider characteristics, allowing a maximum post-weighting standardized mean difference ≤0.01 for all covariates; we also exactly matched the groups on laterality (right vs left kidney) and intended surgical approach (open, laparoscopic, robotic). We used bivariate multilevel mixed-effects generalized linear models accounting for hospital-level clustering to compare the study outcomes between the FHGS and VHTS groups. Results After weighting, the FHGS and VHTS groups comprised 2952 and 795 patients, respectively. The observed incidence proportion of the primary outcome of hemostasis-related complications during the index admission was similar between the groups (8.6% for FHGS vs 9.0% for VHTS, difference 0.4% [95% CI −3.2% to 2.5%], P =0.808). Differences between the FHGS and VHTS groups were not statistically significant for any of the secondary outcomes. Conclusion Endoscopic surgical staplers have become common for transection of the renal vessels during radical nephrectomy, with FHGS and VHTS being the predominant reload types. In this retrospective study of 3747 non-donor patients undergoing radical nephrectomy, use of FHGS vs VHTS reloads was associated with similar clinical and economic outcomes.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.