Favipiravir finished dosage was approved for emergency use in many countries to treat SARS-CoV-2 patients. A specific, accurate, linear, robust, simple, and stabilityindicating HPLC method was developed and validated for the determination of degradation impurities present in favipiravir film-coated tablets. The separation of all impurities was achieved from the stationary phase (Inert sustain AQ-C18, 250 Â 4.6 mm, 5-μm particle) and mobile phase. Mobile phase A contained KH 2 PO 4 buffer (pH 2.5 ± 0.05) and acetonitrile in the ratio of 98:2 (v/v), and mobile phase B contained water and acetonitrile in the ratio of 50:50 (v/v). The chromatographic conditions were optimized as follows: flow rate, 0.7 mL/min; UV detection, 210 nm; injection volume, 20 μL; and column temperature, 33 C. The proposed method was validated per the current International Conference on Harmonization Q2 (R1) guidelines. The recovery study and linearity ranges were established from the limit of quantification to 150% optimal concentrations. The method validation results were found to be between 98.6 and 106.2% for recovery and r 2 = 0.9995-0.9999 for linearity of all identified impurities. The method precision results were achieved below 5% of relative standard deviation. Forced degradation studies were performed in chemical and physical stress conditions. The compound was sensitive to chemical stress conditions. During the study, the analyte degraded and converted to unknown degradation impurities, and its molecular mass was found using the LC-MS technique and established degradation pathways supported by reaction of mechanism. The developed method was found to be suitable for routine analysis of research and development and quality control.
Pibrentasvir (PIB) was approved for treating hepatitis C patients. A specific, accurate, linear, robust, and stability-indicating method was developed and validated for determining degradation impurities present in the PIB drug substance by studying the quality by design (QbD) principles. All identified degradation impurities were separated with the stationary phase HALO C18, 150 mm × 4.6 mm, 2.7 μm. Mobile phase A contains pH 2.5 phosphate buffer and acetonitrile in the ratio of (70:30, v/v), and mobile phase B contains water and acetonitrile in the ratio of (30:70, v/v), respectively. The chromatographic conditions were optimized, such as flow rate of 0.8 mL/min, UV detection at 252 nm, injection volume of 20 μL, and column temperature of 40 °C. The proposed method was validated per the current ICH Q2 (R1) guidelines. The recovery study and linearity ranges were established from limit of quantification (LOQ) to 300% optimal concentrations. The method validation results were between 98.6% and 106.2% for recovery, and linearity r 2 was more than 0.999 for all identified impurities. The method precision results achieved below 5% relative standard deviation (RSD). The forced degradation results demonstrated that the drug was sensitive to chemical stress conditions. During the stress study, degrading impurities were identified by the LC-MS technique and the mechanism pathway. A QbD-based experimental design (DoE) approach was used to establish the robustness of the method.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.