Thermal nondestructive testing can be used to inspect reinforced concrete supports that are widely used in various industries. Corrosion damage is a typical defect found in these supports. Corrosion usually starts as a separation between the concrete and the steel rebar. Damage is exacerbated by pressure that is caused by the formation of corrosion products. The most logical method for using IR to detect corrosion or a disbond would be to heat up the rebar by resistive or inductive heating. In both cases, monitoring the dynamic temperature distributions on the pole allows for the evaluation of reinforcement quality. The thermal properties of steel, concrete, air, and corrosion products differ greatly. The magnitude of temperature anomalies and their behavior over time depend on the presence of corrosion products, air gaps, and the quality of contact between rebar and concrete.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.