Mitral valve injury after blunt chest trauma is a rare occurrence. We recently admitted a patient with severe traumatic mitral regurgitation who was successfully treated with surgery. Review of the literature aimed at taking an inventory of cases of traumatic nonpenetrating mitral insufficiency that were operated on, since the earliest report in 1964. Eighty-two cases were found and analyzed allowing for a better understanding of the epidemiology, etiology, natural history, pathology, and treatment of this rare condition. The most common lesions reach the papillary muscles (PM), followed by the chordae and then the mitral valve leaflets. Among the 82 cases reported that have been treated with surgery, 57% required a valve replacement. More than half of the patients had a PM injury with a complete or partial rupture. When the rupture is complete, and especially when it involves the anterior PM, the clinical picture is most always acute with clinically important hemodynamic repercussions, often necessitating emergency surgery, most of the time with mitral valve replacement. One must always suspect traumatic mitral injury after blunt chest trauma. The most common mitral lesions affect the PM. The clinical course can be indolent or devastating, and most often requires urgent or delayed surgical treatment, either with mitral valve repair or replacement.
Full or more than target flow was achieved in 97% of the patients studied undergoing CPB with self-expanding venous cannulas and gravity drainage. Remote venous cannulation with self-expanding cannulas provides similar flows as central cannulation. Augmentation of venous return is no longer necessary.
First-degree atrio-ventricular (AV) block is defined as a PR interval longer than 200 ms. If too long, it can become clinically relevant and may mimic a pacemaker syndrome. We report the case of a young woman with a long PR interval, probably congenital, with episodes of syncope and dizziness since childhood. Pseudo-pacemaker syndrome is rare and is a Class IIa recommendation for a pacemaker implantation. A dual-chamber pacemaker was implanted and short AV delay was programmed, with rapid clinical improvement.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.