This invited review covers research areas of central importance for orthopaedic and maxillofacial bone tissue repair, including normal fracture healing and healing problems, biomaterial scaffolds for tissue engineering, mesenchymal and foetal stem cells, effects of sex steroids on mesenchymal stem cells, use of platelet-rich plasma for tissue repair, osteogenesis and its molecular markers. A variety of cells in addition to stem cells, as well as advances in materials science to meet specific requirements for bone and soft tissue regeneration by addition of bioactive molecules, are discussed.
We report a systematic review and meta-analysis of the peer-reviewed literature focusing on metal sensitivity testing in patients undergoing total joint replacement (TJR). Our purpose was to assess the risk of developing metal hypersensitivity post-operatively and its relationship with outcome and to investigate the advantages of performing hypersensitivity testing. We undertook a comprehensive search of the citations quoted in PubMed and EMBASE: 22 articles (comprising 3634 patients) met the inclusion criteria. The frequency of positive tests increased after TJR, especially in patients with implant failure or a metal-on-metal coupling. The probability of developing a metal allergy was higher post-operatively (odds ratio (OR) 1.52 (95% confidence interval (CI) 1.06 to 2.31)), and the risk was further increased when failed implants were compared with stable TJRs (OR 2.76 (95% CI 1.14 to 6.70)). Hypersensitivity testing was not able to discriminate between stable and failed TJRs, as its predictive value was not statistically proven. However, it is generally thought that hypersensitivity testing should be performed in patients with a history of metal allergy and in failed TJRs, especially with metal-on-metal implants and when the cause of the loosening is doubtful.
Polyethylene (PE) wear has been shown to be a problem in long-term joint replacement using metal-on-PE bearing. The use of metallic heads articulating with metallic cups could solve this problem: success will be enhanced if wear and corrosion of the articulating surfaces are maintained at a low level. New models with metal-on-metal bearing have been proposed, to be used mainly for young subjects: such coupling seems to have a reduced release, but it is unclear yet if the medium-term corrosion rate is really negligible or, on the contrary, it is significantly higher than in the metal-on-PE bearing. Aim of our study was the comparison of ion release in the serum of two groups of patients who had the same type of stable cementless prosthesis, but different bearing: twenty-six patients with metal-on-metal (Group A) and fifteen patients with metal-on-PE bearing (Group B) were examined. The follow-up was 14-38 months for group A and 18-34 months for group B. The serum concentration of chromium (Cr), cobalt (Co) and molybdenum (Mo) was measured. Twenty-two patients before surgery were used for comparison (Group C). The reference values were obtained from a population of twenty-two healthy subjects (Group D). Our findings indicate that metal-on-metal bearings produce a significantly higher systemic release of cobalt and chromium (ng/ml) when compared with levels found in metal-on-PE, pre-surgery and reference groups. Such a high release should induce to improve the bearing materials or, at least, to study the biologic fate of metal ions and consequently their long-term effects. In such a way a risk-to-benefit ratio for the patient could be established.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.