IntroductionVariability among manufacturers of urine dipsticks, respective to their accuracy and measurement range, may lead to diagnostic errors and thus create a serious risk for the patient. Our aims were to determine the level of agreement between 12 most commonly used urine dipsticks in Croatia, examine their accuracy for glucose and total protein and to test their repeatability.Materials and methodsA total of 75 urine samples were used to examine comparability and accuracy of 12 dipstick brands (Combur 10 TestM, ChoiceLine 10, Combur 10 TestUX, ComboStik 10M, ComboStik 11M, CombiScreen 11SYS, CombiScreen 10SL, Combina 13, Combina 11S, Combina 10M, UriGnost 11, Multistix 10SG). Agreement between each dipstick and the reference (Combur 10 TestM) was expressed as kappa coefficient (acceptable κ ≥ 0.80). Accuracy for glucose and total protein was tested by comparison with quantitative measurements on analysers: AU400 (Beckman Coulter, USA), Cobas 6000 c501 (Roche Diagnostics, Germany) and Architect plus c4000 (Abbott, USA). Repeatability was assessed on 20 replicates (acceptable > 90%).ResultsBest agreement was achieved for glucose, total protein and nitrite (11/11, k > 0.80) and the lowest for bilirubin (5/5, k < 0.60). Sensitivities for total protein were 41-75% (AU400) and 56-92% (Cobas and Architect); while specificities were 41-75% (AU400, Cobas, Architect). Dipsticks’ sensitivity and specificity for glucose were 68-98%. Most of the dipsticks showed unacceptable repeatability (6/12, < 90%) for one parameter, most prominently for pH (3/12, < 90%).ConclusionsMost commonly used dipsticks in Croatia showed low level of agreement between each other. Moreover, their repeatability varies among manufacturers and their accuracy for glucose and proteins is poor.
Introduction: It has been recommended that each laboratory modify their critical result reporting practices to reflect the clinical needs of their patient populations. The aim of this survey was to assess how well critical laboratory values defined by the Croatian Chamber of Medical Biochemists (CCMB) correspond to the needs of the physicians at University hospital “Sveti Duh” (Zagreb, Croatia). Materials and methods: We conducted a survey among physicians from five departments in our hospital. Physicians were asked general questions about critical risk results (if and how they want to be informed). A list of critical risk results defined by the CCMB was offered and physicians were asked to revise the existing critical risk results and suggest adding new parameters. Obtained data were presented as numbers. Where the number of observations was low, ratios were used. Results: Survey response rate was 43% (52/121). Majority (48/52) wants to be informed of critical risk results, either personally (31/48) or through a colleague (32/48). They prefer to be informed about critical risk results of prothrombin time, platelet count, haemoglobin, glucose, creatinine, sodium and potassium. Revisions in the CCMB critical risk result list are proposed by 13 out of 48 physicians. Neonatologists approved the CCMB’s list. Conclusions: Although most critical risk results defined by the CCMB correspond well to the needs of the physicians in our hospital, some revisions are necessary to meet the particular needs of individual departments. Communication of critical risk results to those who have requested laboratory testing is highly appreciated practice.
Introduction: In line with the national recommendations, Croatian medical laboratories report urine test strip qualitative analysis results using a categorized scale with defined number of categories. Since concentration ranges for measured analytes have not been provided by national professional authority, it is up to the laboratories to define their own categories. The aim of study was to assess the comparability of concentrations assigned to different categories used in reporting the results of dipstick urinalysis in Croatian laboratories. Material and methods: A questionnaire was e-mailed to all Croatian medical laboratories (N = 195). They were asked to provide the number of categories and respective concentrations for each parameter. Data were described as numbers and percentages. Values above the upper reference range limit, which were assigned as normal and/or trace category, were considered as false negative. Results: Response rate was 71% (139/195). Seventy percent (98/139) of laboratories report their results with either higher (77/98; 79%) or lower (2/98; 2%) number of categories, relative to the national recommendation, whereas 19/98 (19%) report their results as concentrations. Great heterogeneity of reporting categories was observed. Multiple categories were assigned to same concentrations and there was a large overlap of concentrations for most categories. Considerable proportion of laboratories reported false negative results for ketones (42%), leukocytes (30%) and glucose (21%). Conclusions: The concentrations assigned to categories used to report the results of dipstick urinalysis are not comparable among Croatian medical laboratories. There is an urgent need for harmonization and standardization of reporting the results of urine dipstick analysis in Croatia.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.