Background
During the last two decades, vacuum-assisted wound therapy has been successfully transferred to an endoscopic treatment approach of various upper and lower gastrointestinal leaks called endoscopic vacuum therapy (EVT). As mostly small case series are published in this field, the aim of our systematic review and meta-analysis was to evaluate the efficacy and safety of EVT in the treatment of colorectal leaks.
Methods
A systematic search of MEDLINE/PubMed and Cochrane databases was performed using search terms related to EVT and colorectal defects (anastomotic leakage, rectal stump insufficiency) according to the PRISMA guidelines. Randomized controlled trials (RCTs), observational studies, and case series published by December 2020 were eligible for inclusion. A meta-analysis was conducted on the success of EVT, stoma reversal rate after EVT as well as procedure-related complications. Statistical interferences were based on pooled estimates from random effects models using DerSimonian-Laird estimator.
Results
Only data from observational studies and case series were available. Twenty-four studies reporting on 690 patients with colorectal defects undergoing EVT were included. The mean rate of success was 81.4% (95% CI: 74.0%–87.1%). The proportion of diverted patients was 76.4% (95% CI: 64.9%–85.0%). The mean rate of ostomy reversal across the studies was 66.7% (95% CI: 58.0%–74.4%). Sixty-four patients were reported with EVT-associated complications, the weighted mean complication rate across the studies was 12.1% (95% CI: 9.7%–15.2%).
Conclusions
Current medical evidence on EVT in patients with colorectal leaks lacks high quality data from RCTs. Based on the data available, EVT can be seen as a feasible treatment option with manageable risks for selected patients with colorectal leaks.
Background
Incisional hernia remains a frequent problem after midline laparotomy. This study compared a short stitch to standard loop closure using an ultra-long-term absorbent elastic suture material.
Methods
A prospective, multicentre, parallel-group, double-blind, randomized, controlled superiority trial was designed for the elective setting. Adult patients were randomly assigned by computer-generated sequence to fascial closure using a short stitch (5 to 8 mm every 5 mm, USP 2-0, single thread HR 26 mm needle) or long stitch technique (10 mm every 10 mm, USP 1, double loop, HR 48 mm needle) with a poly-4-hydroxybutyrate-based suture material (Monomax®). Incisional hernia assessed by ultrasound 1 year after surgery was the primary outcome.
Results
The trial randomized 425 patients to short (n = 215) or long stitch technique (n = 210) of whom 414 (97.4 per cent) completed 1 year of follow-up. In the short stitch group, the fascia was closed with more stitches (46 (12 s.d.) versus 25 (7 s.d.); P < 0.001) and higher suture-to-wound length ratio (5.3 (2.2 s.d.) versus 4.0 (1.3 s.d.); P < 0.001). At 1 year, seven of 210 (3.3 per cent) patients in the short and 13 of 204 (6.4 per cent) patients in the long stitch group developed incisional hernia (odds ratio 1.97, 95 per cent confidence interval 0.77 to 5.05; P = 0.173).
Conclusion
The 1-year incisional hernia development was relatively low with clinical but not statistical difference between short and long stitches.
Registration number: NCT01965249 (http://www.clinicaltrials.gov)
Enteroatmospheric fistulas (EAF) are rare but challenging and morbid complications of abdominal surgery and require time- as well as resource-consuming management. Furthermore, they severely affect patients' quality of life. Several treatment modalities for EAF management are described in the literature. We describe 3 consecutive cases of EAF treatment by employing negative pressure wound therapy (NPWT) along with either a special silicone fistula adapter or a Silo-Vac-like system in another case to isolate the fistula from the remaining abdominal wound. Spontaneous fistula closure was achieved in 2 of the 3 cases, and surgical resection of the small bowel segment harbouring EAF opening was possible in a third case after wound conditioning. The rate of fistula closure was 100% (n = 3/3). Compartmentalisation of the contaminated area using NPWT accelerated healing of the open abdominal wound remarkably. In summary, we present a useful tool for the challenging management of EAF and review the literature on different treatment options of EAF available today.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.