Purpose: The primary objective was to compare T2-FRFSE and T2-PROPELLER sequences for image quality. The secondary objective was to compare the ability to detect prostate lesions at MRI in the presence and absence of motion artefact using the 2 sequences. Methods: 99 patients underwent 3 T MRI examination of the prostate, including T2-FRFSE and T2-PROPELLER sequences. All patients underwent prostate biopsy. Two independent readers rated overall image quality, presence of motion artefact, and blurring for both sequences using a 5-point Likert scale. Scores were compared for the whole group and for subgroups with and without significant motion artefact. Outcome for lesion detection at an MRI threshold of PI-RADS score ≥3 was compared between T2-FRFSE and T2-PROPELLER. Results: The overall image quality was not significantly different between T2-FRFSE and T2-PROPELLER sequences (3.74 vs. 3.93, p = 0.275). T2-PROPELLER recorded a lesser degree of motion artefact (score 4.53 vs. 3.78, p <0.0001), but demonstrated greater image blurring (score 3.29 vs. 3.73, p <0.001). However, in a subgroup of patients with significant motion artefact on T2-FRFSE, the T2-PROPELLER sequence demonstrated significantly higher image quality (3.46 vs. 2.49, p <0.001). T2-FRFSE and T2-PROPELLER showed comparable positive predictive values for lesion detection at 93.2% and 97.7%, respectively. Conclusions: T2-PROPELLER provides higher quality imaging in the presence of motion artefact, but T2-FRFSE is preferred in the absence of motion. T2-PROPELLER is therefore recommended as a secondary T2 sequence when imaging requires repeat acquisition due to motion artefact.
PurposeThe risk of complications associated with femoral venous catheterization could be potentially reduced if the procedure was performed at the location where the cross-sectional area (CSA) of the vessel is the largest. The diameter of the femoral vein depends on leg position as well as the distance from the inguinal ligament. We determined the CSA of the right femoral vein in three different leg positions at two distances from the inguinal ligament.Subjects and methodsInformed consent was given by 205 healthy volunteers aged 19–39 years, mean: 23±3 years (108 women, 97 men). Ultrasonographic examinations were performed using a linear 14-MHz transducer with CSA measurements in three leg positions: abduction, abduction+external rotation, abduction+external rotation+90° knee flexion/frog-leg position; at levels 20 mm caudally to the inguinal ligament, and 20 mm caudally to the inguinal crease.ResultsWe found significant differences in mean values of CSA in three leg positions regardless of the measurement level. The largest mean CSA (114 mm2±35 mm2) was found at the proximal level in the frog-leg position. There was a significant association of the CSA with sex and height. The CSA in males was greater than in females in all leg positions at the level of 20 mm caudally to the inguinal crease, while 20 mm caudally to the inguinal ligament the CSA was larger in females. The CSA of 25% of the femoral vein was smaller than 45.0 mm2 at the proximal level, and 31.5 mm2 at the distal level, which refers to diameters of 5.3 mm, and 4.5 mm, respectively.ConclusionsThe cross-sectional area of the femoral vein is the largest in the frog-leg position, and depends on gender.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.