ObjectivesThe aim of this study was to assess the accuracy and precision of a novel application of 3-material decomposition (3MD) with virtual monochromatic images (VMIs) in the dual-energy computed tomography (DECT) assessment of monosodium urate (MSU) and hydroxyapatite (HA) phantoms compared with a commercial 2-material decomposition (2MD) and dual-thresholding (DT) material decomposition methods.Materials and MethodsMonosodium urate (0.0, 3.4, 13.3, 28.3, and 65.2 mg/dL tubes) and HA (100, 400, and 800 mg/cm3 tubes) phantoms were DECT scanned individually and together in the presence of the foot and ankle of 15 subjects. The raw data were decomposed with 3MD-VMI, 2MD, and DT to produce MSU-only and HA-only images. Mean values of 10 × 10 × 10–voxel volumes of interest (244 μm3) placed in each MSU and HA phantom well were obtained and compared with their known concentrations and across measurements with subjects' extremities to obtain accuracy and precision measures. A statistical difference was considered significant if P < 0.05.ResultsCompared with known phantom standards, 3MD-VMI was accurate for the detection of MSU concentrations as low as 3.4 mg/dL (P = 0.75). In comparison, 2MD was limited to 13.3 mg/dL (P = 0.06) and DT was unable to detect MSU concentrations below 65.2 mg/L (P = 0.16). For the HA phantom, 3MD-VMI and 2MD were accurate for all concentrations including the lowest at 100 mg/cm3 (P = 0.63 and P = 0.55, respectively). Dual-thresholding was not useful for the decomposition of HA phantom. Precision was high for both 3MD-VMI and 2MD measurements for both MSU and HA phantoms. Qualitatively, 3MD-VMI MSU-only images demonstrated reduced beam-hardening artifact and voxel misclassification, compared with 2MD and DT.ConclusionsThree-material decomposition-VMI DECT is accurate for quantification of MSU and HA concentrations in phantoms and accurately detects a lower concentration of MSU than either 2MD or DT. For concentration measurements of both MSU and HA phantoms, 3MD-VMI and 2MD have high precision, but DT had limitations. Clinical implementation of 3MD-VMI DECT promises to improve the performance of this imaging modality for diagnosis and treatment monitoring of gout.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.