Background As new SARS-CoV-2 variants of concern emerge, there is a need to scale up testing to minimize transmission of the Coronavirus disease 2019 (COVID-19). Many countries especially those in the developing world continue to struggle with scaling up reverse transcriptase polymerase reaction (RT-PCR) to detect SARS-CoV-2 due to scarcity of resources. Alternatives such as antigen rapid diagnostics tests (Ag-RDTs) may provide a solution to enable countries scale up testing. Methods In this study, we evaluated the Panbio™ and STANDARD Q Ag-RDTs in the laboratory using 80 COVID-19 RT-PCR confirmed and 80 negative nasopharyngeal swabs. The STANDARD Q was further evaluated in the field on 112 symptomatic and 61 asymptomatic participants. Results For the laboratory evaluation, both tests had a sensitivity above 80% (Panbio™ = 86% vs STANDARD Q = 88%). The specificity of the Panbio™ was 100%, while that of the STANDARD Q was 99%. When evaluated in the field, the STANDARD Q maintained a high specificity of 99%, however the sensitivity was reduced to 56%. Conclusion Using Ag-RDTs in low resource settings will be helpful in scaling-up SARS-CoV-2 testing, however, negative results should be confirmed by RT-PCR where possible to rule out COVID-19 infection.
Background As new SARS-CoV-2 variants of concern emerge, there is a need to scale up testing to minimize transmission of the Coronavirus disease 2019 (COVID-19). Many countries especially those in the developing world continue to struggle with scaling up reverse transcriptase polymerase reaction (RT-PCR) to detect SARS-CoV-2 due to scarcity of resources. Alternatives such as antigen rapid diagnostics tests (Ag-RDTs) may provide a solution to enable countries to scale up testing. Methods In this study, we evaluated the PanbioTM and STANDARD Q Ag-RDTs in the laboratory using 80 COVID-19 RT-PCR confirmed and 80 negative nasopharyngeal swabs. The STANDARD-Q was further evaluated in the field on 112 symptomatic and 61 asymptomatic participants. Results For the laboratory evaluation, both tests had a sensitivity above 80% (PanbioTM = 86% vs STANDARD Q = 88%). The specificity of the PanbioTM was 100%, while that of the STANDARD Q was 99%. When evaluated in the field, the STANDARD Q maintained a high specificity of 99%, however the sensitivity was reduced to 56%. Conclusion Using Ag-RDTs in low resource settings will be helpful, however, negative results should be confirmed by RT-PCR where possible to rule out COVID-19 infection.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.