Background Continuing efforts have been made to develop minimally invasive surgery techniques for THA. One of the most commonly performed of these techniques is the mini-posterior approach. All reported series using this approach describe surgical detachment of the short external rotators of the hip. In 2008, Penenberg et al. described an innovative surgical technique that preserves the short external rotators. We present the results of a singleincision modification of this technique in 135 patients.
Description of TechniqueThis technique is based on preservation of all of the short external rotators of the hip with the exception of the piriformis or conjoined tendon. This single-incision technique required the development of specialized instrumentation for exposure and reaming of the acetabulum. The specialized retractors also successfully minimized trauma to the skin and subcutaneous tissue. Methods For the 135 patients undergoing THA with this technique, we analyzed demographic and operative data. We recorded complications, evaluated postoperative clinical function using the Harris hip score, and assessed cup abduction angle, cup anteversion, and stem alignment on radiographs. Minimum followup was 14 months (mean, 22 months; range, 14-33 months). Results There were no dislocations, no sciatic nerve palsies, no wound complications, and low transfusion rates (8%). The postoperative Harris hip score averaged 96.5 (range, 87-100). Overall acetabular cup abduction angle averaged 41°(range, 21°-49°) and anteversion averaged 21°(range, 15°-27°). Four percent and 2% of femoral components were inserted into more than 2°varus and 2°v algus alignment, respectively.
A 25-year-old woman who was 20 weeks pregnant developed systemic lupus erythematosus with acquired ichthyosis and pyoderma gangrenosum. The course of these dermatoses suggests that an immunopathological mechanism was implicated in their pathogenesis.
The DS approach caused less soft-tissue damage than the DA approach. However the clinical relevance is unknown. Further clinical outcome studies, radiographic evaluation of component position, gait analyses and serum biomarker levels are necessary to evaluate and corroborate the safety and efficacy of the DS approach. Cite this article: Bone Joint J 2016;98-B1036-42.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.