Evaluating measurement uncertainty of a physical quantity is a mandatory requirement for laboratories within the recognition ISO/IEC 17025 certification to access reliability of measured results. In this work, the uncertainty of ionizing radiation measurements such as air-kerma, personal dose equivalent Hp(d) was evaluated based on GUM method and Monte Carlo method. An uncertainty propagation software has been developed for evaluation of the measurement uncertainty more convenient.
An automated panoramic irradiator with a 241Am-Be neutron source of 5 Ci is installed in a bunker-type medium room at the Institute for Nuclear Science and Technology (INST) for calibration of neutron devices. Bonner Sphere Spectrometer (BSS) formed by 6 spheres plus bare detector, with cylindrical, almost point like, 6LiI(Eu) scintillator and 2 different spectral unfolding FRUIT and BUNKIUT codes are used to characterize the neutron field in different measurement points along the irradiation bench. The neutron field is also simulated by MCNP5 software and compared with measurements performed by the BSS. The paper shows the main results obtained in terms of neutron spectra at fixed distances from the source as well as their neutron fluence rate (totaland direct) and ambient dose equivalent rate. These values measured by the BSS with two unfolding FRUIT and BUNKIUT codes are in good agreement with that of simulated by MCNP5 within 10%.
For personal radiation dose monitoring, electronic personal dosimeters (EPD), also known as active personal dosimeter (APD), using silicon diode detector have the advantage capability of measuring and displaying directly the exposure results of gamma, beta and neutron radiations in real time. They are mainly considered as good complement to passive dosimeters to satisfy ALARA principle in the radiation protection. In this paper, the meansurement methods and algorithms for evaluating personal dose equivalents such as Hp(10) and Hp(0.07) from air-kerma are studied and developed in two directions: the first, named energy correction method based on incident energy determined by the ratio of two detector responses with the different filter configurations; the second new method is carried out in the way that matching the shape of a detector’s energy response curve to the kerma-to-personal dose equivalent conversion function provides an approximate means of determining the dose equivalent without the need to resolve the actual incident energies. The algorithm has also been experimentally verified at Secondary Standards Dosimetry Laboratory (SSDL) of INST by the beam of radiation defined in ISO 4037-1. The obtained results of personal dose equivalents with errors almost less than 30% in energy range from 20 keV to 1.5 MeV are partially met the EPD design requirements according to the IEC 61526 Standard. The work and results of described in this paper are important basics for design and construction of completed electronic personal dosimeter.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.