No abstract
Aims to evaluate the incidence of cardiac arrhythmias during a lockdown period due to COVID-19 pandemics in a population followed by remote monitoring through implanted cardiac defibrillators. Methods and results In this retrospective, multicentre cohort study, we included 574 remotely monitored automatic (AICD) and cardiac resynchronization devices (CRT-D) recipients implanted before January 1st 2019 at seven Hospitals of Campania Region, comparing the incidence of arrhythmias occurred during the lockdown period due to COVID-19 epidemics (from March 9th to May 1st 2020) with the arrhythmias rate of the corresponding period in 2019. An effective retrospective data collection was performed through remote monitoring, as this tool allows the direct transfer of the the information stored by the implantable devices to medical personnel. During the lockdown period, we observed ventricular tachyarrhythmias (ventricular tachycardia or fibrillation) in 25 (4.8%) patients as compared to 12 (2.3%) during the corresponding 2019 period (p < 0.04); new-onset atrial fibrillation was detected in 38 (8.2%) subjects during lockdown period and in 24 (5.2%) during the reference period (p < 0.004). Conclusion During pandemics lockdown period we observed an higher incidence of arrhythmic events in ICD/CRT-D patients followed up through device remote monitoring by seven hospitals of Campania region.
Funding Acknowledgements Type of funding sources: None. Background Radiofrequency (RF) catheter ablation of the cavo-tricuspid isthmus (CTI) is an established treatment for typical right atrial flutter (RAFL). However, whether local tissue impedance (LI) is able to predict effective CTI ablation and what LI drop values during ablation should be used to judge a lesion as effective remains to be established. Purpose We aimed to investigate the ability of LI to predict ablation efficacy in patients (pts) with RAFL and to characterize the CTI in terms of LI. Methods Consecutive pts undergoing RAFL ablation from the CHARISMA registry were enrolled at 9 centers. A novel RF ablation catheter with dedicated algorithm (DirectSense - DS -) was used to measure LI at the distal electrode of this catheter. RF applications (RFC) were targeted to a minimum LI drop of 10 Ω within 30 seconds and were stopped when a maximum cutoff LI drop of <40 Ω was observed. Successful single RFC was defined according with a split in two separate potentials (SPL), reduction of voltage (RedV) by at least 50% or changes at unipolar EGM (UPC). Agreement among criteria was evaluated. Ablation endpoint was the creation of bidirectional conduction block (BDB) across the isthmus. Results A total of 279 ablation spot lesions were delivered in 30 pts (mean RFC 9 ± 6 lesions per pt): 106 (38%) at anterior, 115 (41%) at mid and 58 (21%) at posterior portions of the CTI. BDB was obtained in all cases and no complications were observed. The median RFC delivery time was 30 [19–45] seconds per lesion. 132 (47%), 150 (54%) and 86 (31%) ablation spots were effective according with SPL, RedV and UPC, respectively. Complete agreement of all the criteria was reached in 70% of the cases. The mean LI was 104.4 ± 11Ω prior to ablation and 92.1 ± 11Ω after ablation (p < 0.0001, mean absolute LI drop 12.2 ± 7Ω, mean time to LI drop 13 ± 8 seconds). Effective ablation spots showed a higher LI drop compared with ineffective sites at each single criteria (16.6 ± 7Ω vs 8.3 ± 4Ω for SPL, p < 0.0001; 16.1 ± 6Ω vs 7.8 ± 5Ω at for RedV, p < 0.0001; 19 ± 6Ω vs 9.2 ± 4Ω for UPC, p < 0.0001) and LI drop values significantly increase according to the number of criteria satisfied (ranging from 7.5Ω % -no criteria- to 19.1 -all criteria-). A 15Ω cut-off value for LI (AUC 0.91, sensitivity = 67%, specificity = 92%, p < 0.0001) was associated with the achievement of all criteria with an OR of 21.9 (95%CI: 11.1 to 43.5, p < 0.0001) and a positive predictive value of 76%. Starting LI and LI drop seem to be higher at mid-septal areas. Conclusion In our preliminary experience, a LI-guided approach of CTI seems to be safe and effective in RAFL ablation. The magnitude of LI drop was associated with effective lesion formation and conduction block and could be used as a marker of ablation efficacy.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.