Background:
Measurement of myocardial blood flow (MBF) with single photon emission computed tomography (SPECT) is feasible using cardiac cameras with solid-state detectors. SPECT MBF has been shown to be accurate when compared with positron emission tomography MBF measured in the same patients. However, the value of a test result applied to an individual patient depends strongly on the precision or repeatability of the test. The purpose of our study is to measure the precision of SPECT MBF measurements using
99m
Tc-tetrofosmin and a solid-state cardiac camera.
Methods:
SPECT MBF was measured in 30 patients and repeated at a mean interval of 18 days. MBF was evaluated from images with and without attenuation correction based on a separately acquired CT scan. The dynamic images were processed independently by 2 operators using in-house kinetic analysis software that applied a 1-tissue-compartment model. The K1 rate constant was converted to MBF using previously determined extraction fraction corrections. Correction for patient body motion was applied manually.
Results:
The average coefficient of variation (COV) in the differences between the 2 MBF measurements was between 28% and 31%. The interobserver COV was between 11% and 15%. Myocardial flow reserve is the ratio of MBF measured at stress and rest, and the COV is correspondingly higher. The COV for the difference in repeated myocardial flow reserve was 33% to 38%, whereas the interobserver COV was 13% to 22%.
Conclusions:
The COV for the difference in SPECT MBF measurements obtained on separate days is 28% to 31%. The corresponding COV for myocardial flow reserve is 33% to 38%.
The originally published version of this article contained typographical errors in the units of photon sensitivity. The units of counts Á MBq-1 Á min-1 and kcounts Á mCi-1 Á min-1 were mistakenly recorded as counts Á MBq Á min and kcounts Á mCi Á min respectively. The original article has been corrected. Publisher's Note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.