Purpose: We report an approach, termed Repeated k-t-subsampling and artifact-minimization (ReKAM), for removing motion artifacts in free-breathing abdominal MRI. The method is particularly valuable for challenging patients who may not hold their breath for a long time or have irregular respiratory rate. Methods: The ReKAM framework comprises one acquisition module and two reconstruction modules. A fast MRI sequence is used to repeatedly acquire multiple sets of k-t space data. Motion artifacts are then minimized by two reconstruction modules: (a) a bootstrapping module in k-t-space is used to identify a low-artifact image; (b) a constrained reconstruction module that integrates projection onto convex set (POCS) and multiplexed sensitivity encoding (MUSE), termed POCSMUSE, is applied to further remove residual artifact. The ReKAM framework is compatible with different pulse sequences, and generally applicable to irregular data sampling patterns in k-space. Free-breathing fast spin-echo MRI data, acquired from healthy volunteers and patients, were used to evaluate the developed ReKAM method. Results: Experimental results show that the ReKAM technique can produce high-quality freebreathing images with the artifact levels comparable to that of breath-holding MRI. Conclusion: The ReKAM framework improves the quality of free-breathing abdominal MRI data, and is compatible with various MRI pulse sequences.
Background: Current 4D-MRI techniques are prone to breathing-variation-induced motion artifacts. This study developed a novel method for motion-robust multi-cycle 4D-MRI using probability-based multi-cycle sorting to overcome this deficiency. Methods: The main cycles were first extracted from the breathing signal. 3D k-space data were then sorted using a result-driven method for each main cycle. The new method was tested on a 4D-extended cardiactorso (XCAT) phantom with a patient and an artificially generated breathing curve. For comparison, the k-space data were sorted using conventional phase sorting to generate single-cycle 4D-MRI images. Signalto-noise ratio (SNR) of tumor and liver, tumor volume consistency, and average intensity projection (AIP) accuracy were compared between the two methods. The original phantom images were used as references for the evaluation. Results: The new method showed improved tumor-to-liver SNR and tumor volume consistency as compared to 3D k-space phase sorting in both the simulated artificial and real patient breathing signals. For the artificial breathing cycles, the average tumor-to-liver SNR and standard deviation (SD) of tumor volume were 2.53 and 3.80% for cycle 1, 2.24 and 6.16% for cycle 2 of probability-based sorting as compared to 1.47 and 21.83% obtained using the phase sorting method; for the patient breathing curve, values of 1.99 and 2.71%, 1.97 and 3.29%, 1.88 and 4.16% were observed for cycle 1, cycle 2 and cycle 3 of probability-based sorting, versus 1.44 and 7.20% for phase sorting method. Furthermore, the AIP accuracy was improved in the probability-based sorting approach when compared to phase sorting, with the average intensity difference per voxel reduced from 0.39 to 0.15 for the artificial curve, and from 0.46 to 0.21 for the patient curve. Conclusions: We demonstrated the feasibility of probability-based 3D k-space sorting for motion-robust multi-cycle 4D-MRI reconstruction with breathing variation induced motion artifact reduction compared with conventional 2D image sorting and 3D phase sorting methods. This new technique can potentially improve the accuracy of radiation treatment guidance for mobile targets.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.