Abstract. This study presents a new concept for estimating the pollutant emission rates of a site and its main facilities using a series of atmospheric measurements across the pollutant plumes. This concept combines the tracer release method, local-scale atmospheric transport modelling and a statistical atmospheric inversion approach. The conversion between the controlled emission and the measured atmospheric concentrations of the released tracer across the plume places valuable constraints on the atmospheric transport. This is used to optimise the configuration of the transport model parameters and the model uncertainty statistics in the inversion system. The emission rates of all sources are then inverted to optimise the match between the concentrations simulated with the transport model and the pollutants' measured atmospheric concentrations, accounting for the transport model uncertainty. In principle, by using atmospheric transport modelling, this concept does not strongly rely on the good colocation between the tracer and pollutant sources and can be used to monitor multiple sources within a single site, unlike the classical tracer release technique. The statistical inversion framework and the use of the tracer data for the configuration of the transport and inversion modelling systems should ensure that the transport modelling errors are correctly handled in the source estimation. The potential of this new concept is evaluated with a relatively simple practical implementation based on a Gaussian plume model and a series of inversions of controlled methane point sources using acetylene as a tracer gas. The experimental conditions are chosen so that they are suitable for the use of a Gaussian plume model to simulate the atmospheric transport. In these experiments, different configurations of methane and acetylene point source locations are tested to assess the efficiency of the method in comparison to the classic tracer release technique in coping with the distances between the different methane and acetylene sources. The results from these controlled experiments demonstrate that, when the targeted and tracer gases are not well collocated, this new approach provides a better estimate of the emission rates than the tracer release technique. As an example, the relative error between the estimated and actual emission rates is reduced from 32 % with the tracer release technique to 16 % with the combined approach in the case of a tracer located 60 m upwind of a single methane source. Further studies and more complex implementations with more advanced transport models and more advanced optimisations of their configuration will be required to generalise the applicability of the approach and strengthen its robustness.
New methylene blue (NMB+) and methylene violet (MV) are known for their photosensitizing properties for singlet oxygen ((1)O2) generation upon visible-light irradiation, and various examples of their use in the photodynamic inactivation of microorganisms and for photomedicinal purposes have been reported. However, their photophysical properties have never been extensively and systematically analyzed and compared. In the current work, we studied their absorption and fluorescence behavior relative to their parent compound, methylene blue (MB+), detected the transient species generated upon excitation of the photosensitizers and determined their quantum yields of singlet oxygen production. We could measure very high quantum yields of singlet oxygen production for all the studied compounds. NMB+ appeared similar to MB+, even though it produces (1)O2 much more efficiently, and was slightly influenced by the solvent. MV, in contrast, was much more sensitive to the chemical environment, and the transient species formed upon irradiation were different in methanol and acetonitrile. It appeared to be a very good singlet oxygen sensitizer, but the influence of the chemical environment should be carefully considered for any application. The comparative characterization of these sensitizers will represent a support for the determination and the understanding of the photochemical mechanisms occurring by using these phenothiazine dyes for various photobiological applications.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.