The detectors proposed for future e+e-colliders (ILC and CLIC) demand a high level of precision in the measurement of jet energies. Various technologies have been proposed for the active layers of the digital hadron calorimetry to be used in conjunction with the Particle Flow Algorithm (PFA) approach. The High Energy Physics group of the University of Texas at Arlington has been developing Gas Electron Multiplier (GEM) detectors for use as the calorimeter active gap detector. To understand this application of GEMs, two kinds of prototype GEM detectors have been tested. One has 30x30 cm 2 active area double GEM structure with a 3 mm drift gap, a 1 mm transfer gap and a 1 mm induction gap. The other one has two 2x2 cm 2 GEM foils in the amplifier stage with a 5 mm drift gap, a 2 mm transfer gap and a 1 mm induction gap. We will summarize the results of tests of these prototypes, using cosmic rays and sources, in terms of their applicability to a digital hadron calorimeter system. We will discuss plans for the construction of 1m 2 layers of GEM digital hadron calorimetry to be used as part of a 1m 3 stack to be used in a major test beam study of hadronic showers.
The High Energy Physics group of the University of Texas at Arlington Physics Department has been developing Gas Electron Multiplier (GEM) detectors for use as the sensitive gap detector in digital hadron calorimeters (DHCAL) for the future International Linear Collider. In this study, two kinds of prototype GEM detectors have been tested. One has 30x30 cm 2 active area double GEM structure with a 3 mm drift gap, a 1 mm transfer gap and a 1 mm induction gap. The other one has two 2x2 cm 2 GEM foils in the amplifier stage with a 5 mm drift gap, a 2 mm transfer gap and a 1 mm induction gap. We present characteristics of these detectors obtained using high-energy charged particles, cosmic ray muons and 106 Ru and 55 Fe radioactive sources. From the 55 Fe tests, we observed two well-separated X-ray emission peaks and measured the chamber gain to be over 6500 with a high voltage of 395 V across each GEM electrode. Both the spectra from cosmic rays and the 106 Ru fit well to Landau distributions as expected from minimum ionizing particles. We also present the chamber performance after high dosage exposure to radiation as well as the pressure dependence of the gain and correction factors. Finally, we discuss the quality test results of the first set of large scale GEM foils and discuss progress and future plans for constructing large scale (100cmx100cm) GEM detectors.
No abstract
No abstract
The High Energy Physics group of the University of Texas at Arlington has been developing gas electron multiplier detectors to use them as sensitive gap detectors in digital hadron calorimeters for the International Linear Collider, a future high energy particle accelerator. For this purpose, we constructed numerous GEM detectors that employ double GEM layers. In this study, two kinds of prototype GEM detectors were tested; one with 28x28 cm 2 active area double GEM structure with a 3 mm drift gap, a 1 mm transfer gap and a 1 mm induction gap and the other with two 3x3 cm 2 GEM foils in the amplifier stage with a 5 mm drift gap, a 2 mm transfer gap and a 1 mm induction gap. The detectors' characteristics from exposure to high-energy charged particles and other radiations were measured using cosmic rays and 55 Fe radioactive source. From the 55 Fe tests, we observed two well separated characteristic X-ray emission peaks and confirmed the detectors' functionality. We also measured chamber gains to be over 6000 at a high voltage of 395 V across each GEM electrode. The responses to cosmic rays show the spectra that fit well to Landau distributions as expected from minimum ionizing particles.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.