Solar photo-Fenton process has been extensively reported to be highly efficient in the remediation of complex industrial wastewater containing several families of pollutants such as pharmaceuticals, dyes, pesticides, derivatives of wine, etc. Moreover, solar photo-Fenton mathematical modelling regarded as a powerful tool for scaling-up and process control purposes is hindered by the complexity and variability of its reaction mechanism which depends on the particular wastewater under study. In this work, non-biodegradable cork boiling wastewater has been selected as a case study for solar photo-Fenton dynamic modelling by using MATLAB® software. First of all physic-chemical pretreatment was applied attaining chemical oxygen demand (COD) reductions between 43 and 70 % and total suspended solid (TSS) reductions between 23 % and 59 %. After solar photo-Fenton treatment, COD decreased between 45 and 90 % after consumptions of H2O2 varying around 1.9 and 2.4 g/L. Individual calibration of the semi-empirical model by using experimental results made it possible to perfectly predict hydrogen peroxide variations throughout the treatment. It must be highlighted that slight deviations between predictions and experimental data must be attributed to important changes in wastewater characteristics.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.