This experimental study aimed to determine the activity of a near-UVA (405nm) LED ceiling system against the SARS-CoV-2 virus. The ceiling system comprised 17 near-UVA LED lights with a radiant power of 1.1 Watt/each centred at 405 nm wavelength. A 96multiwell plate, fixed to a wooden base, was inoculated with suspensions of VERO E6 cell cultures infected with SARS-CoV-2 virus and irradiated at a distance of 40 cm with a dose of 20.2 J/cm 2 for 120 minutes. The collected suspensions were transferred to VERO cell culture plates and incubated for 3 days. The maximum measurable log reduction obtained, starting from a concentration of 10 7.2 TCID50/mL, was 3.0 log 10 and indicated inhibition of SARS-CoV-2 replication by the near-UVA LED ceiling system. Near-UVA light at a 405-nm wavelength is emerging as a potential alternative treatment for localized
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.