Magnetization vs. applied field measurements ( -loops) were taken on YBCO thin films with filaments patterned into them. The YBCO was deposited onto LaAlO 3 substrates using PLD, and the filaments were formed by laser ablation.-loops were taken at 4.2 K in fields up to 9 T using a vibrating sample magnetometer technique, the field applied perpendicular to the film width, . The losses were seen to be greatly reduced by filament width reductions following the standard expression 10. The penetration field was also well described by the standard "high field" expression = (0 4 ) ln( + 1), where is the film thickness. The regimes of applicability of the loss expression were investigated, in particular near . A more general form of the loss equation was obtained and compared with the high-field approximation. The result was that although still increased in proportion to , the rate of increase decreased as approached .Index Terms-AC loss, hysteretic loss, penetration field, YBCO.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.