Background
The aim of this study is to evaluate results in terms of local control (LC), overall survival (OS), and toxicity profile and to better identify factors influencing clinical outcome of skull base chordoma treated with proton therapy (PT) and carbon ion radiotherapy (CIRT).
Methods
We prospectively collected and analyzed data of 135 patients treated between November 2011 and December 2018. Total prescription dose in the PT group (70 patients) and CIRT group (65 patients) was 74 Gy relative biological effectiveness (RBE) delivered in 37 fractions and 70.4 Gy(RBE) delivered in 16 fractions, respectively (CIRT in unfavorable patients). LC and OS were evaluated using the Kaplan–Meier method. Univariate and multivariate analyses were performed, to identify prognostic factors on clinical outcomes.
Results
After a median follow-up of 44 (range, 6–87) months, 14 (21%) and 8 (11%) local failures were observed in CIRT and PT group, respectively. Five-year LC rate was 71% in CIRT cohort and 84% in PT cohort. The estimated 5-year OS rate in the CIRT and PT group was 82% and 83%, respectively. On multivariate analysis, gross tumor volume (GTV), optic pathways, and/or brainstem compression and dose coverage are independent prognostic factors of local failure risk. High rate toxicity grade ≥3 was reported in 11% of patients.
Conclusions
Particle radiotherapy is an effective treatment for skull base chordoma with acceptable late toxicity. GTV, optic pathways, and/or brainstem compression and target coverage were independent prognostic factors for LC.
Key Points
• Proton and carbon ion therapy are effective and safe in skull base chordoma.
• Prognostic factors are GTV, organs at risk compression, and dose coverage.
• Dual particle therapy and customized strategy was adopted.
Purpose: Only few centers worldwide treat intraocular tumors with proton therapy, all of them with a dedicated beamline, except in one case in the USA. The Italian National Center for Oncological Hadrontherapy (CNAO) is a synchrotron-based hadrontherapy facility equipped with fixed beamlines and pencil beam scanning modality. Recently, a general-purpose horizontal proton beamline was adapted to treat also ocular diseases. In this work, the conceptual design and main dosimetric properties of this new proton eyeline are presented. Methods: A 28 mm thick water-equivalent range shifter (RS) was placed along the proton beamline to shift the minimum beam penetration at shallower depths. FLUKA Monte Carlo (MC) simulations were performed to optimize the position of the RS and patient-specific collimator, in order to achieve sharp lateral dose gradients. Lateral dose profiles were then measured with radiochromic EBT3 films to evaluate the dose uniformity and lateral penumbra width at several depths. Different beam scanning patterns were tested. Discrete energy levels with 1 mm water-equivalent step within the whole ocular energy range (62.7-89.8 MeV) were used, while fine adjustment of beam range was achieved using thin polymethylmethacrylate additional sheets.Depth-dose distributions (DDDs) were measured with the Peakfinder system. Monoenergetic beam weights to achieve flat spread-out Bragg Peaks (SOBPs) were numerically determined. Absorbed dose to water under reference conditions was measured with an Advanced Markus chamber, following International Atomic Energy Agency (IAEA) Technical Report Series (TRS)-398 Code of Practice. Neutron dose at the contralateral eye was evaluated with passive bubble dosimeters. Results: Monte Carlo simulations and experimental results confirmed that maximizing the air gap between RS and aperture reduces the lateral dose penumbra width of the collimated beam and increases the field transversal dose homogeneity. Therefore, RS and brass collimator were placed at about 98 cm (upstream of the beam monitors) and 7 cm from the isocenter, respectively. The lateral 80%-20% penumbra at middle-SOBP ranged between 1.4 and 1.7 mm depending on field size, while 90%-10% distal fall-off of the DDDs ranged between 1.0 and 1.5 mm, as a function of range. Such values are comparable to those reported for most existing eye-dedicated facilities. Measured SOBP doses were in very good agreement with MC simulations. Mean neutron dose at the contralateral eye was 68 lSv/Gy. Beam delivery time, for 60 Gy relative biological effectiveness (RBE) prescription dose in four fractions, was around 3 min per session. Conclusions: Our adapted scanning proton beamline satisfied the requirements for intraocular tumor treatment. The first ocular treatment was delivered in August 2016 and more than 100 patients successfully completed their treatment in these 2 yr.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.