6 renal transplant patients, seen at the Mayo Clinic between July 1982 and April 1983, received Minnesota antilymphoblast globulin (MALG) for treatment of allograft rejection and demonstrated warm-acting ‘auto’-antibodies during such therapy. These antibodies represented xenogeneic reactivity in equine MALG, rather than the products of patient-derived immune responses, since they were not detected before or after the period of therapy with this immunosuppressive agent in any of the 6 cases. They interfered with crossmatch procedures for red cell transfusion, and were only variably removed by autoabsorption techniques. Heat treatment of sera containing MALG-related red cell antibodies was ineffective in abrogating their reactivity and also compromised the reactivity of some red cell alloantibodies which were tested as controls. Transfusion of ‘least-incompatible’ red blood cells had no adverse effects in 2 cases where it was necessitated by clinical circumstances, despite an inability to obtain suitable serological samples for crossmatching
6 renal transplant patients, seen at the Mayo Clinic between July 1982 and April 1983, received Minnesota antilymphoblast globulin (MALG) for treatment of allograft rejection and demonstrated warm-acting 'auto'-antibodies during such therapy. These antibodies represented xenogeneic reactivity in equine MALG, rather than the products of patient-derived immune responses, since they were not detected before or after the period of therapy with this immunosuppressive agent in any of the 6 cases. They interfered with crossmatch procedures for red cell transfusion, and were only variably removed by autoabsorption techniques. Heat treatment of sera containing MALG-related red cell antibodies was ineffective in abrogating their reactivity and also compromised the reactivity of some red cell alloantibodies which were tested as controls. Transfusion of 'least-incompatible' red blood cells had no adverse effects in 2 cases where it was necessitated by clinical circumstances, despite an inability to obtain suitable serological samples for crossmatching.
A 79-year-old woman with a diagnosis of lower gastrointestinal bleeding was found to have a complementdependent anti-Jk sup(a) i n her serum. The anti -Jk sup(a) was evaluated by the antiglobulin technique with polyspecific, anti-C3, and anti-IgG antihuman globulin (AHG). A variety of Sensitization and detection methods were used, including the prewarmed saline technique, enzyme treatment of test cells, a low-ionic additive solution (LISS), 22 percent albumin, Polybrcnc, and an increased scrum/cell ratio. The anti -Jk sup(a) was detected only when polyspecific AHG and anti-C3 were used compared to anti-IgG, regardless of the selected enhancement technique. Anti-C3 gave weaker reactions than polyspecific AHG. IgG subclassing was inconclusive. The anti -Jk sup(a) was not detected when plasma was substituted for serum. The use of polyspecific versus IgG AHG in prctrmsfusion testing is discussed. In 1951, Allen et al . sup( 1) reported the first case of hemolytic disease of the newborn (HDN) associated with anti-Jk sup(a). Since then, other cases have been reported in which anti-Jk sup(a) caused severe HDN sup(2) or, in one case, caused no clinical symptoms. sup(3) However, the evidence that anti-Jk sup(a) 4-6 and -Jk sup(b) 7 cause acute and delayed hemolytic transfusion reactions is well documented.Kidd system antibodies are often difficult to identify, as they are rarely potent, can show a dosage effect by reacting more strongly with Jk(a+b-) than with Jk(a + b +) cells, and frequently become nondetectable
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.