Objectives. To evaluate the utility of fetal abdominal wall thickness (AWT) for predicting intrapartum complications amongst mothers with pregestational type 2 diabetes. Methods. This was a historical cohort study of pregnant mothers with pregestational type 2 diabetes delivering at a Canadian tertiary-care center between January 1, 2014, and December 31, 2018. Delivery records were reviewed to collect information about demographics and peripartum complications. Stored fetal ultrasound images from 36 weeks’ gestation were reviewed to collect fetal biometry and postprocessing measurement of AWT performed in a standardized fashion by 2 blinded and independent observers. The relationship between fetal AWT was then correlated with risk of intrapartum complications including emergency Caesarean section (CS) and shoulder dystocia. Results. 216 pregnant women with type 2 diabetes had planned vaginal deliveries and were eligible for inclusion. Mean maternal age was 31.3 years, and almost all were overweight or obese at the time of delivery (96.8%). Overall, the incidence of shoulder dystocia and emergency intrapartum CS was 7.4% and 17.6%, respectively. There was no difference in mean fetal AWT between those having a spontaneous vaginal delivery (8.2 mm (95% CI 7.9-8.5)) and those needing emergency intrapartum CS (8.1 mm (95% CI 7.4-8.8); p = 0.71 ) or shoulder dystocia (8.7 mm (95% CI 7.9-9.5); p = 0.23 ). There was strong interobserver correlation of AWT measurements ( r = 0.838 ; p < 0.00001 ). The strongest association with intrapartum complications was birthweight ( p = 0.003 ): with birthweight > 4000 grams, the relative risk of shoulder dystocia or CS is 2.75 (95% CI 1.74-4.36; p < 0.001 ). Conclusions. There was no obvious benefit of AWT measurement at 36 weeks for predicting shoulder dystocia or intrapartum CS amongst women with type 2 diabetes in our population. The strongest predictor of intrapartum complications remained birthweight, and so studies for improving estimation of fetal weight and evaluating the role of intrapartum ultrasound for predicting risk of delivery complications are still needed.
Introduction It is frequently quoted in mainstream media that the clitoris has “8000 nerve endings.” However, no study has yet quantified the number of nerve fibers (axons) innervating the human clitoris. The dorsal nerves of the clitoris (DNCs) are the primary source of sensation and somatic clitoral innervation. Therefore, reporting the number of axons in the DNCs is an important step in our understanding of clitoral innervation and sexual response with implications for many fields of medical practice. The purpose of this study is to quantify the mean number of axons in the human DNCs and to report the approximate mean number of nerve fibers that innervate the human glans clitoris. Methods DNC samples were obtained from 7 transmasculine patients undergoing gender-affirming phalloplasty surgery. At the time of nerve coaptation, a small excess of the DNC (5 mm) was collected for analysis at the proximal level of the clitoral body, just distal of the emergence of the DNCs from underneath the pubic symphysis. Samples were placed into 3% glutaraldehyde fixative, postfixed in 1% osmium tetroxide, and serially dehydrated in ethanol and toluene. Samples were then embedded in araldite, sectioned on an ultramicrotome into 1-μm cross sections, and counterstained with 1% toluidine blue. Histomorphometric evaluation was performed at 1000x magnification with a Leitz Laborlux S microscope and image analysis software (Clemex Vision Professional) to obtain an axon counts. Descriptive statistics were performed to yield a mean and standard deviation of the number of axons in the DNCs. Assuming anatomic symmetry between bilateral DNCs, mean total number of somatic nerve fibers innervating the human glans clitoris was obtained by doubling the mean count of the DNCs. Results Seven sample DNCs were collected. Of those, 5 were analyzed as 2 did not have sufficient nerve tissue present. The mean number of nerve fibers in the human DNCs was 5140 (SD = 218.4). The mean number of myelinated nerve fibers innervating the human clitoris was 10,281 (SD = 436.8). Conclusion This study is the first to report the number of axons in the human DNC, at a mean 5140. Given the bilateral nature of clitoral innervation and symmetry of anatomic structures, the approximate mean number of myelinated axons that innervate the human glans clitoris is 10,280. When the uncaptured unmyelinated fibers and contributions from the cavernosal innervation are accounted for, it is clear that far Moree than 8000 axons innervate the human clitoris.
Objectives: To show the efficacy of first trimester placental localisation in prediction of migration of low-lying placenta in cases of previous Caesarean section (CS) and the prediction of placenta accreta. Methods: The study was performed on 75 cases with history of one or more CS, single fetus, with placenta either covering or within 20mm from the internal cervical os. Patients were examined during the first visit at 11-14 weeks of gestation by transabdominal then transvaginal ultrasound. Direction of cord insertion was recorded; criteria of abnormal placental invasion were searched for using 2D and colour Doppler ultrasound. Patients were reexamined again during 24-32 weeks of gestation to report placental migration to the upper uterine segment. Cases that found in the lower segment within 20mm or covering the internal os were reported as placenta previa. Results: 87% of cases showed placental migration in third trimester. The direction of umbilical cord attachment to placenta showed highest sensitivity in prediction of placenta previa when recorded early in first trimester in comparison to the distance from the leading placental edge to the centre of the internal os and placental position. Conclusions: First trimester localisation of placenta by ultrasonography could predict placenta previa in cases with a history of previous CS and low-lying placenta.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.