The National Aeronautics and Space Administration (NASA) Soil Moisture Active Passive (SMAP) satellite is scheduled for launch in January 2015. In order to develop robust soil moisture retrieval algorithms that fully exploit the unique capabilities of SMAP, algorithm developers had identified a need for long-duration combined active and passive L-band microwave observations. In response to this need, a joint Canada-U.S. field experiment (SMAPVEX12) was conducted in Manitoba (Canada) over a six-week period in 2012. Several times per week, NASA flew two aircraft carrying instruments that could simulate the observations the SMAP satellite would provide. Ground crews collected soil moisture data, crop measurements, and biomass samples in support of this campaign. The objective of SMAPVEX12 was to support the development, enhancement, and testing of SMAP soil moisture retrieval algorithms. This paper details the airborne and field data collection as well as data calibration and analysis. Early results from the SMAP active radar retrieval methods are presented and demonstrate that relative and absolute soil moisture can be delivered by this approach. Passive active L-band sensor Manuscript (PALS) antenna temperatures and reflectivity, as well as backscatter, closely follow dry down and wetting events observed during SMAPVEX12. The SMAPVEX12 experiment was highly successful in achieving its objectives and provides a unique and valuable data set that will advance algorithm development.Index Terms-Passive microwave, soil moisture, Soil Moisture Active Passive (SMAP), synthetic aperture radar.
Soil spatial heterogeneity poses a challenge to accurate soil moisture determination. Remote sensing, in particular, using sensors that acquire data at microwave frequencies, is being used to overcome this challenge. In situ soil moisture monitoring can be used to validate remotely sensed surface soil moisture estimates and as inputs for agronomic and hydrologic models. Nine in situ soil moisture stations were established in Manitoba (Canada) and instrumented with Stevens Hydra Probes. The sensors were installed in triplicate with vertical orientation at the surface and with horizontal orientation at the 5-, 20-, 50-, and 100-cm depths. To ensure accuracy of the measured soil moisture, both laboratory and ield calibrations were conducted. These calibrated soil moisture values were compared with the probe default values and those generated using published calibrations. Overall, the results showed that the ield calibration was superior (coeficient of determination r 2 of 0.95) to the laboratory calibration (r 2 of 0.89). In addition, coarse-textured sites generally performed better than the ine-textured, high cation exchange capacity (CEC) sites. At the Kelburn site with high clay and CEC, the use of ield calibration reduced the root mean square error from 0.188 to 0.026 m 3 m −3 . However, at the low clay and CEC Treherne site, gains in accuracy were minimal, about 0.005 m 3 m −3 . The laboratory calibration consistently underestimated soil moisture at all the evaluation sites, whereas both Topp and Logsdon calibrations overestimated soil moisture.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.