In this paper, a mathematical description of the control method on the basis of difference correction [1] applying to sampled-data systems is considered. The difference correction is an efficient way to improving the dynamic characteristics of the pulse power converters, which work is described by difference equations. Proposed method allows transforming a difference equation so that the roots of the characteristic equation become equal to zero. Herewith the maximum speed of convergence of transient to a steady value in the field of it's environ under perturbations of system parameters is achieved. Using the example of a system for stabilizing the load current of a buck converter it is shown that the transient is completed within two or three periods.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.