Background Noise in the operating room (OR) contributes to miscommunication among team members and may negatively impact patient outcomes. Objectives This study aimed to quantify noise levels during endoscopic sinus and skull base surgery. The secondary aim was to understand how OR team members perceive noise during endoscopic sinus and skull base surgery. Methods Noise levels were measured using the validated phone application SoundMeter X 10.0.4 (r1865) (Faber Acoustical, Utah, USA) at the ear-level of the surgeon, scrub nurse, circulating nurse, and anesthesiologist. At the end of each surgery, OR team members were asked to complete a six-question questionnaire about noise during that surgery. Results One thousand four hundred and two noise measurements were recorded across 353 trials. The loudest mean noise measurement was 84.51 dB and maximum noise measurement was 96.21 dB at the ear-level of the surgeon. Noise was significantly higher at the ear-level of the surgeon and scrub nurse in comparison to the circulating nurse (p = .000) and anesthesiologist (p = .000). Forty percent of questionnaire respondents believed noise was a problem and 38% stated that noise caused communication issues during surgery. Conclusion Surgeons and scrub nurses have significantly higher noise exposure in comparison to circulating nurses and anesthesiologists during endoscopic sinus and skull base surgery. For these members of the OR team, noise is also identified as problematic and causing issues with communication. Mechanisms to reduce potential noise may be implemented to improve communication and patient outcomes in endoscopic sinus and skull base surgery.
The objective of this short scientific communication is to describe and test a strategy to overcome communication barriers in coronavirus disease 2019 (COVID-19) era otolaryngology operating rooms. Thirteen endoscopic sinus surgeries, 4 skull base surgeries, and 1 tracheotomy were performed with powered air-purifying respirators. During these surgeries, surgical team members donned headsets with microphones linked via conference call. Noise measurements and survey responses were obtained and compared to pre–COVID-19 data. Noise was problematic and caused miscommunication as per 93% and 76% of respondents, respectively. Noise in COVID-19 era operating rooms was significantly higher compared to pre–COVID-19 era data (73.8 vs 70.2 decibels, P = .04). Implementation of this headset strategy significantly improved communication. Respondents with headsets were less likely to encounter communication problems (31% vs 93%, P < .001). Intraoperative measures to protect surgical team members during aerosolizing surgeries may impair communication. Linking team members via a conference call is a solution to improve communication.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.