Patients with chronic obstructive pulmonary disease admitted to the ICU for acute exacerbations had abnormal breathing-swallowing interactions and dyspnea, which improved with noninvasive mechanical ventilation. Furthermore, a ventilator device with a simple switch-off pushbutton to eliminate insufflations during swallows prevented swallowing-induced ventilator triggering and postswallow autotriggering.
BackgroundIdentifying patients at high risk of post-extubation acute respiratory failure requiring respiratory or mechanical cough assistance remains challenging. Here, our primary aim was to evaluate the accuracy of easily collected parameters obtained before or just after extubation in predicting the risk of post-extubation acute respiratory failure requiring, at best, noninvasive mechanical ventilation (NIV) and/or mechanical cough assistance and, at worst, reintubation after extubation. MethodsWe conducted a multicenter prospective, open-label, observational study from April 2012 through April 2015. Patients who passed a weaning test after at least 72 h of endotracheal mechanical ventilation (MV) were included. Just before extubation, spirometry and maximal pressures were measured by a technician. The results were not disclosed to the bedside physicians. Patients were followed until discharge or death. ResultsAmong 3458 patients admitted to the ICU, 730 received endotracheal MV for longer than 72 h and were then extubated; among these, 130 were included. At inclusion, the 130 patients had mean ICU stay and endotracheal MV durations both equal to 11 ± 4.2 days. After extubation, 36 patients required curative NIV, 7 both curative NIV and mechanical cough assistance, and 8 only mechanical cough assistance; 6 patients, all of whom first received NIV, required reintubation within 48 h. The group that required NIV after extubation had a significantly higher proportion of patients with chronic respiratory disease (P = 0.015), longer endotracheal MV duration at inclusion, and lower Medical Research Council (MRC) score (P = 0.02, P = 0.01, and P = 0.004, respectively). By multivariate analysis, forced vital capacity (FVC) and peak cough expiratory flow (PCEF) were independently associated with (NIV) and/or mechanical cough assistance and/or reintubation after extubation. Areas under the ROC curves for pre-extubation PCEF and FVC were 0.71 and 0.76, respectively.ConclusionIn conclusion, FVC measured before extubation correlates closely with FVC after extubation and may serve as an objective predictor of post-extubation respiratory failure requiring NIV and/or mechanical cough assistance and/or reintubation in heterogeneous populations of medical ICU patients.ClinicalTrials.gov as #NCT01564745Electronic supplementary materialThe online version of this article (10.1186/s13613-018-0360-3) contains supplementary material, which is available to authorized users.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.