Dentin hypersensitivity (DH) is a common medical condition with underreported prevalence and it is difficult to quantify. This study aimed to investigate whether assessing dental pulp vascular micro-dynamics by laser-Doppler flowmetry (LDF) would be functional for therapeutic evaluation, in contrast to a verbal rating scale (VRS). A split-mouth single-blind randomized study was conducted on seven patients and a total of 36 teeth. Two DH therapeutic methods were employed: (i) fluoride gel; (ii) Nd:YAG radiation combined with fluoride gel. For each tooth, five consecutive LDF determinations of pulp blood flow were made (before and immediately after desensitizing treatment, then after 24 h, 7 days, and 1 month), and the VRS was applied each time. Spearman’s correlation was applied for concurrent validation. Two-way (treatment and patient) repeated measures ANOVA full factorial was applied, followed by Tukey’s post-hoc comparisons and Pillai’s trace multivariate statistic. While VRS scores had moderate reliability, LDF could objectively estimate treatment effects. Based on partial eta-squared values, treatment and patient characteristics were estimated to explain about 84% and 50% of the variability, respectively. In conclusion, LDF is an objective technique that can quantitatively assess DH evolution, and it is effective in reliably monitoring oral health therapeutic interventions.
The heat produced during tooth preparation could be a source of damage for dental pulp, and many variables are involved in this process. The aim of this in vitro study was to evaluate whether the different degrees of wear of the diamond burs significantly influenced the temperature changes in the pulp chamber during tangential veneer preparation. The sample comprised 30 intact permanent monoradicular teeth, randomly assigned to three study groups of 10 teeth each, of which 5 had the pulp tissue preserved and 5 had thermoconductive paste in the pulp chamber. For prosthetic preparation, we used new burs in the first group, burs at their fifth use in the second group, and burs at their eighth use for the third group. The pulp chamber temperature was evaluated at the start, after one minute, and after three minutes of preparation, using a k-type thermocouple. The results of the three-way ANOVA and Tukey post hoc comparisons showed a highly significant effect of the time of measurement, while the pulp condition and the degree of wear of the burs had no effect. In conclusion, the different degrees of wear of conventional diamond burs do not produce statistically significant different changes in the pulp chamber temperature.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.