BackgroundThe aim of this study was to prospectively examine echocardiographic parameters that correlate and predict functional capacity assessed by 6 min walk test (6-MWT) in patients with heart failure (HF), irrespective of ejection fraction (EF).MethodsIn 147 HF patients (mean age 61 ± 11 years, 50.3% male), a 6-MWT and an echo-Doppler study were performed in the same day. Global LV dyssynchrony was indirectly assessed by total isovolumic time - t-IVT [in s/min; calculated as: 60 – (total ejection time + total filling time)], and Tei index (t-IVT/ejection time). Patients were divided into two groups based on the 6-MWT distance (Group I: ≤300 m and Group II: >300 m), and also in two groups according to EF (Group A: LVEF ≥ 45% and Group B: LVEF < 45%).ResultsIn the cohort of patients as a whole, the 6-MWT correlated with t-IVT (r = −0.49, p < 0.001) and Tei index (r = −0.43, p < 0.001) but not with any of the other clinical or echocardiographic parameters. Group I had lower hemoglobin level (p = 0.02), lower EF (p = 0.003), larger left atrium (p = 0.02), thicker interventricular septum (p = 0.02), lower A wave (p = 0.01) and lateral wall late diastolic myocardial velocity a’ (p = 0.047), longer isovolumic relaxation time (r = 0.003) and longer t-IVT (p = 0.03), compared with Group II. In the patients cohort as a whole, only t-IVT ratio [1.257 (1.071-1.476), p = 0.005], LV EF [0.947 (0.903-0.993), p = 0.02], and E/A ratio [0.553 (0.315-0.972), p = 0.04] independently predicted poor 6-MWT performance (<300 m) in multivariate analysis. None of the echocardiographic measurements predicted exercise tolerance in HFpEF.ConclusionIn patients with HF, the limited exercise capacity, assessed by 6-MWT, is related mostly to severity of global LV dyssynchrony, more than EF or raised filling pressures. The lack of exercise predictors in HFpEF reflects its multifactorial pathophysiology.
In chronic stable heart failure patients, in addition to age, systemic hypertension as well as LV asynchrony, as reflected by prolonged t-IVT, are independent predictors of poor exercise capacity.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.