Islet β-cells express both insulin receptors and insulin-signaling proteins. Recent evidence from rodents in vivo and from islets isolated from rodents or humans suggests that the insulin signaling pathway is physiologically important for glucose sensing. We evaluated whether insulin regulates β-cell function in healthy humans in vivo. Glucose-induced insulin secretion was assessed in healthy humans following 4-h saline (low insulin/sham clamp) or isoglycemic-hyperinsulinemic (high insulin) clamps using B28-Asp insulin that could be immunologically distinguished from endogenous insulin. Insulin and C-peptide clearance were evaluated to understand the impact of hyperinsulinemia on estimates of β-cell function. Preexposure to exogenous insulin increased the endogenous insulin secretory response to glucose by ≈40%. C-peptide response also increased, although not to the level predicted by insulin. Insulin clearance was not saturated at hyperinsulinemia, but metabolic clearance of C-peptide, assessed by infusion of stable isotope-labeled C-peptide, increased modestly during hyperinsulinemic clamp. These studies demonstrate that insulin potentiates glucose-stimulated insulin secretion in vivo in healthy humans. In addition, hyperinsulinemia increases C-peptide clearance, which may lead to modest underestimation of β-cell secretory response when using these methods during prolonged dynamic testing. beta cell | type 2 diabetes mellitus | insulin resistance | insulin clearance |
BACKGROUND: C-peptide is a marker of insulin secretion in diabetic patients. We assessed within-and between-laboratory imprecision of C-peptide assays and determined whether serum calibrators with values assigned by mass spectrometry could be used to harmonize C-peptide results.
From the viewpoint of regulatory guidelines, validation of LC-UV and LC-MS based methods have the same requirements. Matrix effects are not considered for most method validations if they do not influence reproducibility or assay linearity. Since matrix effects can strongly suppress ionizaton efficiency and therefore reduce sensitivity, they must be evaluated (and discussed in the context of method development)-prior to method qualification. The severity of matrix effects is directly dependent upon chromatographic performance. We suggest that evaluation of matrix effects and LC efficiency is essential information for method assessment, optimization and transfer to other mass spectrometers, and should be a mandatory part of routine LC/MS method validation. (J Am Soc Mass Spectrom 2005, 16, 1757-1759 LC/MS analysis of low purity biological samples can cause signal suppression, elevated background, and other negative matrix effects. In this situation, it is only possible to increase S/N while simultaneously maintaining high throughput performance by implementing the SRM mode. This, of course, implies a much higher cost of initial investment in sophisticated triple quadrupole instruments. An alternative approach to increasing S/N is to improve the quality of chromatography purification. This decreases matrix effects and makes possible the use of comparatively less expensive single quadrupole instruments while still achieving high analytical performance. Implementation of assays on single quadrupole mass spectrometers can be a good alternative for non-time intensive or budgeted limited projects. Therefore, enhancement of chromatography by implementation of two-dimensional LC methods or even off-line purification of analyte (especially from complex biological matrices) with resultant reduction of matrix effect can significantly improve the sensitivity of mass spectrometers by increasing ionization efficiency of a purer analyte. From the viewpoint of method development and optimization, information about the strength of matrix effects and chromatographic efficiency is important if the goal is to achieve optimum sensitivity.From a regulatory viewpoint, method validation procedures review the following parameters: precision, recovery, specificity, linearity, limit of detection (LOD) and limit of quantitation (LOQ), ruggedness, and robustness [1]. From the viewpoint of regulatory guidelines, validation of LC-UV and LC-MS based methods have the same requirements. In other words, the mass spectrometer is considered just as another type of passive detector. Matrix effects are not considered for most method validations if they do not influence reproducibility or assay linearity. Not directly addressed are technical issues unique to mass spectrometry based assays such as impact of matrix effects on theoretical maximum sensitivity. As mentioned previously, matrix effects can strongly suppress ionization efficiency and sensitivity, and therefore, must be evaluated (and discussed in the context of method development-before method ...
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.