Background Glucose-6-phosphate dehydrogenase (G6PD) deficiency is a common enzyme deficiency, prevalent in many malaria-endemic countries. G6PD-deficient individuals are susceptible to hemolysis during oxidative stress, which can occur from exposure to certain medications, including 8-aminoquinolines used to treat Plasmodium vivax malaria. Accordingly, access to point-of-care (POC) G6PD testing in Brazil is critical for safe treatment of P. vivax malaria. Methodology/Principal findings This study evaluated the performance of the semi-quantitative, POC STANDARD G6PD Test (SD Biosensor, Republic of Korea). Participants were recruited at clinics and through an enriched sample in Manaus and Porto Velho, Brazil. G6PD and hemoglobin measurements were obtained from capillary samples at the POC using the STANDARD and HemoCue 201+ (HemoCue AB, Sweden) tests. A thick blood slide was prepared for malaria microscopy. At the laboratories, the STANDARD and HemoCue tests were repeated on venous samples and a quantitative spectrophotometric G6PD reference assay was performed (Pointe Scientific, Canton, MI). G6PD was also assessed by fluorescent spot test. In Manaus, a complete blood count was performed. Samples were analyzed from 1,736 participants. In comparison to spectrophotometry, the STANDARD G6PD Test performed equivalently in determining G6PD status in venous and capillary specimens under varied operating temperatures. Using the manufacturer-recommended reference value thresholds, the test’s sensitivity at the <30% threshold on both specimen types was 100% (95% confidence interval [CI] venous 93.6%–100.0%; capillary 93.8%–100.0%). Specificity was 98.6% on venous specimens (95% CI 97.9%–99.1%) and 97.8% on capillary (95% CI 97.0%–98.5%). At the 70% threshold, the test’s sensitivity was 96.9% on venous specimens (95% CI 83.8%–99.9%) and 94.3% on capillary (95% CI 80.8%–99.3%). Specificity was 96.5% (95% CI 95.0%–97.6%) and 92.3% (95% CI 90.3%–94.0%) on venous and capillary specimens, respectively. Conclusion/Significance The STANDARD G6PD Test is a promising tool to aid in POC detection of G6PD deficiency in Brazil. Trial registration This study was registered with ClinicalTrials.gov (identifier: NCT04033640).
Background Point-of-care glucose-6-phosphate dehydrogenase (G6PD) testing has the potential to make the use of radical treatment for vivax malaria safer and more effective. Widespread use of G6PD tests as part of malaria case management has been limited, in part due to due concerns regarding product usability, user training, and supervision. This study seeks to assess how well end users can understand the Standard™ G6PD Test (SD Biosensor, Suwon, South Korea) workflow, result output, and label after training. This will ultimately help inform test registration and introduction. Methods Potential G6PD test users who provide malaria case management at three sites in Brazil, Ethiopia, and India were trained on the use of the SD Biosensor Standard G6PD Test and assessed based on their ability to understand the test workflow and interpret results. The assessment was done through a questionnaire, designed to assess product usability against key technical product specifications and fulfill regulatory evidence requirements. Any participant who obtained 85% or above correct responses to the questionnaire was considered to adequately comprehend how to use and interpret the test. Results Forty-five participants, including malaria microscopists, laboratory staff, nurses, and community health workers took part in the study. Seventy-eight percent of all participants in the study (35/45) obtained passing scores on the assessment with minimal training. Responses to the multiple-choice questions indicate that most participants understood well the test intended use, safety claims, and warnings. The greatest source of error regarding the test was around the correct operating temperature. Most test results were also read and interpreted correctly, with the haemoglobin measurement being a more problematic output to interpret than the G6PD measurement. Conclusions These data results show how a standardized tool can be used to assess a user’s ability to run a point-of-care diagnostic and interpret results. When applied to the SD Biosensor Standard G6PD Test, this tool demonstrates that a range of users across multiple contexts can use the test and suggests improvements to the test instructions and training that can improve product usability, increase user comprehension, and ultimately contribute to more widespread effective use of point-of-care G6PD tests. Trial registration: NCT04033640
Background. Point-of-care and decentralized testing for SARS-CoV-2 is critical to inform public health responses. Performance evaluations in priority use cases such as contact tracing can highlight trade-offs in test selection and testing strategies. Methods. A prospective diagnostic accuracy study was conducted among close contacts of COVID-19 cases in Brazil. Two anterior nares swabs (ANS), a nasopharyngeal swab (NPS), and saliva were collected at all visits. Vaccination history and symptoms were assessed. Household contacts were followed longitudinally. Three rapid antigen tests and one molecular method were evaluated for usability and performance against reference RT-PCR on NPS. Results. Fifty index cases and 214 contacts (64 household) were enrolled. Sixty-five contacts were RT-PCR positive during at least one visit. Vaccination did not influence viral load. Gamma variants were most prevalent; Delta emerged increasingly during implementation. Overall sensitivity of evaluated tests ranged from 33% to 76%. Performance was higher among symptomatic cases and cases with Ct<34 and lower among oligo/asymptomatic cases. Assuming a 24-hour time-to-result for RT-PCR, the cumulative sensitivity of an ANS rapid antigen test was >70% and almost 90% after four days. Conclusions. The near immediate time-to-result for antigen tests significantly offsets lower analytical sensitivity in settings where RT-PCR results are delayed or unavailable.
Background Point-of-care and decentralized testing for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is critical to inform public health responses. Performance evaluations in priority use cases such as contact tracing can highlight trade-offs in test selection and testing strategies. Methods A prospective diagnostic accuracy study was conducted among close contacts of coronavirus disease 2019 (COVID-19) cases in Brazil. Two anterior nares swabs (ANS), a nasopharyngeal swab (NPS), and saliva were collected at all visits. Vaccination history and symptoms were assessed. Household contacts were followed longitudinally. Three rapid antigen tests and 1 molecular method were evaluated for usability and performance against reference reverse-transcription polymerase chain reaction (RT-PCR) on nasopharyngeal swab specimens. Results Fifty index cases and 214 contacts (64 household) were enrolled. Sixty-five contacts were RT-PCR positive during ≥1 visit. Vaccination did not influence viral load. Gamma variants were most prevalent; Delta variants emerged increasingly during implementation. The overall sensitivity of evaluated tests ranged from 33% to 76%. Performance was higher among symptomatic cases and those with cycle threshold (Ct) values <34 and lower among oligosymptomatic or asymptomatic cases. Assuming a 24-hour time to results for RT-PCR, the cumulative sensitivity of an anterior nares swab rapid antigen test was >70% and almost 90% after 4 days. Conclusions The near-immediate time to results for antigen tests significantly offsets lower analytical sensitivity in settings where RT-PCR results are delayed or unavailable.
Introduction: Screening for G6PD deficiency can inform disease management including malaria. Treatment with the antimalarial drugs primaquine and tafenoquine can be guided by point-of-care testing for G6PD deficiency. Methods and Findings: Data from similar clinical studies evaluating the performance of the STANDARDTM G6PD Test (SD Biosensor, South Korea) conducted in Bangladesh, Brazil, Ethiopia, India, Thailand, the United Kingdom, and the United States were pooled. Test performance was assessed in a retrospective analysis on capillary and venous specimens. All study sites used spectrophotometry for reference G6PD testing, and either the HemoCue or complete blood count for reference hemoglobin measurement. The sensitivity of the STANDARDTM G6PD Test using the manufacturer thresholds for G6PD deficient and intermediate cases in capillary specimens from 4212 study participants was 100% (95% Confidence Interval (CI): 97.5%–100%) for G6PD deficient cases with <30% activity and 77% (95% CI 66.8%–85.4%) for females with intermediate activity between 30%–70%. Specificity was 98.1% (95% CI 97.6%–98.5%) and 92.8% (95% CI 91.6%–93.9%) for G6PD deficient individuals and intermediate females, respectively. The majority (12/20) of G6PD intermediate females with false normal results had activity levels >60% on the reference assay. Negative predictive values for females with G6PD activity >60% was 99.6% (95% CI 99.1%–99.8%) on capillary specimens. Test sensitivity among 396 P. vivax malaria cases was 100% (69.2%–100.0%) for both deficient and intermediate cases. In the study population, a high proportion of those classified as G6PD deficient or intermediate resulted from true normal cases. Despite this, the majority cases would receive the correct medication and no true G6PD deficient cases would be treated inappropriately. Conclusions: The STANDARD G6PD Test enables safe access to drugs which are contraindicated for individuals with G6PD deficiency. Operational considerations will inform test uptake in specific settings.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.