Public reporting burden for this collection of information is estimated to average 1 hour per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information. Send comments regarding this burden estimate or any other aspect of this collection of information, including suggestions for reducing this burden, THE VIEWS EXPRESSED IN THIS ARTICLE ARE THOSE OF THE AUTHOR AND DO NOT REFLECT THE OFFICIAL POLICY OR POSITION OF THE UNITED STATES AIR FORCE, DEPARTMENT OF DEFENSE, OR THE U.S. GOVERNMENT. AbstractApproved Occupational Safety and Health Administration qualitative respirator fit test methods require the use of a test hood about the subject's head and shoulders. Workers fit tested by this method have commented on the discomfort of being inside the test enclosure. This study was designed to quantify some parameters that might lead to these types of comments. For this study, subjects performed a series of four respirator fit tests. A quantitative and a qualitative fit test were performed with a full facepiece respirator. Then a quantitative and a qualitative fit test were performed with an N95 filtering facepiece respirator. Parameters measured include: subjects height, weight, and age, oxygen and carbon dioxide levels, air temperature, heart rate, arterial oxygen saturation, and Borg Ratio Scale value on breathing exertion. Carbon dioxide levels are significantly higher and oxygen levels are significantly lower in the respirator when the test hood is used during the qualitative fit test. The temperature inside the test hood rose an average 7.5°F in the course of the qualitative fit test of the N95 filtering facepiece device. These stressors are not present during a quantitative respirator fit test. Professionals conducting respirator fit tests should be aware of the physiological burdens that may occur during the qualitative respirator fit test. Some groups may be especially sensitive to this test such as the elderly, pregnant women, persons with pulmonary and/or cardiac disease, or persons with psychological disorders such as anxiety, panic disorders, or claustrophobia.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.