Improving the temporal resolution of single photon detectors has an impact on many applications 1 , such as increased data rates and transmission distances for both classical 2 and quantum 3-5 optical communication systems, higher spatial resolution in laser ranging and observation of shorter-lived fluorophores in biomedical imaging 6 . In recent years, superconducting nanowire single-photon detectors 7,8 (SNSPDs) have emerged as the highest efficiency time-resolving single-photon counting detectors available in the near infrared 9 . As the detection mechanism in SNSPDs occurs on picosecond time scales 10 , SNSPDs have been demonstrated with exquisite temporal resolution below 15 ps [11][12][13][14][15] . We reduce this value to 2.7±0.2 ps at 400 nm and 4.6±0.2 ps at 1550 nm, using a specialized niobium nitride (NbN) SNSPD. The observed photon-energy dependence of the temporal resolution and detection latency suggests that intrinsic effects make a significant contribution.Temporal resolution in SNSPDs, commonly referred to as jitter, is characterized by the width of the temporal distribution of signal outputs with respect to the photon arrival times. This statistical distribution is known as the instrument response function (IRF), and its width is commonly evaluated as
We estimate the depairing current of superconducting nanowire single-photon detectors (SNSPDs) by studying the dependence of the nanowires' kinetic inductance on their bias current. The kinetic inductance is determined by measuring the resonance frequency of resonatorstyle nanowire coplanar waveguides both in transmission and reflection configurations. Bias current dependent shifts in the measured resonant frequency correspond to the change in the kinetic inductance, which can be compared with theoretical predictions. We demonstrate that the fast relaxation model described in the literature accurately matches our experimental data and provides a valuable tool for direct determination of the depairing current. Accurate and direct measurement of the depairing current is critical for nanowire quality analysis, as well as modeling efforts aimed at understanding the detection mechanism in SNSPDs. *
Conventional readout of a superconducting nanowire single-photon detector (SNSPD) sets an upper bound on the output voltage to be the product of the bias current and the load impedance, I B × Z load , where Z load is limited to 50 Ω in standard r.f. electronics. Here, we break this limit by interfacing the 50 Ω load and the SNSPD using an integrated superconducting transmission line taper. The taper is a transformer that effectively loads the SNSPD with high impedance without latching. It increases the amplitude of the detector output while preserving the fast rising edge. Using a taper with a starting width of 500 nm, we experimentally observed a 3.6× higher pulse amplitude, 3.7× faster slew rate, and 25.1 ps smaller timing jitter. The results match our numerical simulation, which incorporates both the hotspot dynamics in the SNSPD and the distributed nature in the transmission line taper. The taper studied here may become a useful tool to interface high-impedance superconducting nanowire devices to conventional low-impedance circuits.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.