Purpose Iodination of rectal hydrogel spacer increases the computed tomography (CT) visibility. The effect of iodinated hydrogel spacer material on the accuracy of proton dosimetry has not been fully studied yet. We presented a systematic study to determine the effect of iodination on proton dosimetry accuracy during proton therapy (PT). Methods PT plans were designed for 20 prostate cancer patients with rectal hydrogel spacer. Three variations of hydrogel density were considered. First, as the ground truth, the true elemental composition of hydrogel true material (TM), verified by our measurement of spacer stopping power ratio, was used for plan optimization and Monte Carlo dose calculation. The dose distribution was recalculated with (1) no material (NM) override based on the CT intensity of the iodinated spacer, and (2) the water material (WM) override, where spacer material was replaced by water. The plans were compared with the ground truth using the metrics of gamma index (GI) and dosimetric indices. Results The iodination of hydrogel spacer affected the proton dose distribution with the NM scenario showing the most deviation from the ground truth. The iodination of spacer resulted in a notable increase in CT intensity and led to the treatment planning systems mistreating the iodinated spacer as a high‐density material. Among the structures adjacent to the target, neurovascular bundles showed the largest dose difference, up to 350 cGy or about 5% of the prescribed dose with NM. Compared to the WM scenario, dose distribution similarity and GI passing ratios were lower in the NM scenario. Conclusion The inaccurate CT intensity‐based material for iodinated spacer resulted in errors in PT dose calculation. We found that the error was negligible if the iodinated spacer was replaced with water. Water density can be used as a clinically accessible and convenient alternative material override to true spacer material.
PurposeIn this study, we aim to further evaluate the accuracy of ultrasound tracking for intra-fraction pancreatic tumor motion during radiotherapy by a phantom-based study.MethodsTwelve patients with pancreatic cancer who were treated with stereotactic body radiation therapy were enrolled in this study. The displacement points of the respiratory cycle were acquired from 4DCT and transferred to a motion platform to mimic realistic breathing movements in our phantom study. An ultrasound abdominal phantom was placed and fixed in the motion platform. The ground truth of phantom movement was recorded by tracking an optical tracker attached to this phantom. One tumor inside the phantom was the tracking target. In the evaluation of the results, the monitoring results from the ultrasound system were compared with the phantom motion results from the infrared camera. Differences between infrared monitoring motion and ultrasound tracking motion were analyzed by calculating the root-mean-square error.ResultsThe 82.2% ultrasound tracking motion was within a 0.5 mm difference value between ultrasound tracking displacement and infrared monitoring motion. 0.7% ultrasound tracking failed to track accurately (a difference value > 2.5 mm). These differences between ultrasound tracking motion and infrared monitored motion do not correlate with respiratory displacements, respiratory velocity, or respiratory acceleration by linear regression analysis.ConclusionsThe highly accurate monitoring results of this phantom study prove that the ultrasound tracking system may be a potential method for real-time monitoring targets, allowing more accurate delivery of radiation doses.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.