Abstract. In the article the analysis of the modernization of the condensing unit. Thermal calculations and design of the condensing unit of the Kalininskaya nuclear power plant was conducted. Extension of service life of the operating NPP power units is one of the most important tendencies of the modern stage of nuclear power engineering development and the most efficient funds investment for preserving generating capacities. The data indicate when modernizing the condensing unit, its cooling area was increased for about 4,000 m 2 due to increasing number of tubes. In addition, tube geometrical dimensions were changed; the wall thickness was reduced from 1 and 2 mm to 0.7 and 1.25 mm respectively.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.