This report describes the case of a 48-year-old white woman who was found to have an entirely pigmented optic disc in an otherwise normal eye. Pigmentation of the optic disc is an uncommon finding. The possible explanations of this physiologic variant are discussed.
Purpose:
To evaluate outcomes of an ab externo surgical technique combining cyclopexy with partial-thickness scleral flap dissection and suture reattachment of ciliary muscle and cryopexy through partial-scleral bed for cyclodialysis cleft repair.
Materials and Methods:
Consecutive patients in a tertiary academic practice with cyclodialysis cleft confirmed by gonioscopy or ultrasound biomicroscopy and had received the combined procedure were reviewed. Primary outcomes included differences between the preoperative and postoperative best-corrected visual acuity (BCVA) and intraocular pressure (IOP). Secondary outcomes included complications and additional surgeries.
Results:
Six consecutive patients (eyes) from October 2006 to November 2012 (6 y) were enrolled. No patient had received prior laser or surgical treatment for cyclodialysis cleft. Patient’s age ranged from 14 to 81 years (median=37 y). Follow-up ranged from 1 to 72 months (median=12 mo). The cyclodialysis clefts of 3 patients (50%) were caused by blunt injuries and the other 3 (50%) from complicated intraocular surgery. Preoperative BCVA ranged from 20/40 to counting fingers with mean IOP of 2.3±2.1 mm Hg (range, 0 to 6 mm Hg). Final postoperative BCVA ranged from 20/20 to hand motions with mean IOP of 11.3±5.7 mm Hg (range, 3 to 18 mm Hg). Five patients (83%) had an increase in IOP and recovery of vision to 20/50 or better at the final visit (including further surgeries). No complication was noted and no additional cyclopexy was required.
Conclusions:
Combined ab externo cyclopexy with partial-thickness scleral flap dissection and suture reattachment of the ciliary muscle and cryopexy delivered on the partial-thickness scleral bed is safe and effective as primary surgical repair for cyclodialysis cleft.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.